Voltage Supply
Check incoming voltage supply at Line 1 to neutral.
There should be a voltage reading of 120 VAC.
Fan Switch
See procedure for checking on page 26.
Conveyor Switch
Check for 120 VAC to conveyor switch. If no
voltage is present, trace wiring back to the fan
switch. WITH POWER OFF: Check continuity
between switch terminals.
Conveyor Fuse (3A)
Check, replace if necessary.
Fuseholder
Check, replace if necessary.
Conveyor Control(Stepper)
Transformer
Check for 120 VAC supply to primary of
transformer, if voltage is not present, trace wiring
back to the fuse-holder. If voltage is present, check
for output voltage from the transformer secondary.
NOTE: this control transformer outputs (2)
secondary voltages. Red Leads 29 VAC Brown
Leads 10 VAC If BOTH secondary voltages are not
present, replace the transformer.
Speed Adjustment
Potentiometer
This is a 0 to 50k ohm,10 turn potentiometer. WITH
POWER OFF: remove the 3 pin potentiometer
cable plug from the motor control board. With a
digital multimeter, check the ohm reading across
the red lead to the black lead, this reading should
be 50k ohms ± 5% as the potentiometer is rotated
through its 10 turn rotation. Place the meter leads
on the red lead and white lead. Rotating the
potentiometer slowly, from low to high, the meter
should show an even transition from 0 to 50K ohms
± 5% through the 10 turn rotation of the
potentiometer. There should be no dead or open
spots through the 10 turns of the potentiometer.
Check all three leads to ground. There should be
no continuity to ground. If any of the above checks
fail, replace the potentiometer.
Conveyor Motor(Stepper)
Control
NOTE: if the conveyor drive motor becomes
jammed or begins to run at an uncontrolled speed,
the conveyor motor will stop running. To reset, turn
off the conveyor switch, wait 10 seconds, turn the
conveyor switch on. If the motor does not run after
attempting re-set, check for 2-29 VAC across the
motor terminals 1 to 2 and 3 to 5 on the conveyor
motor control. If voltage is not present at both sets
of terminals, replace control
Conveyor will not
run(S/N Q19078 &
Up1000 Series) (S/N
Q14791 & Up1200
Series)
Conveyor Drive (Stepper)
Motor
Check the drive sprocket on motor out-put shaft to
insure that it is tight.. Check motor windings –
measurements should be approximately 2 ohms.
Terminal 1-5, 2-6, 3-7, 4-8 WITH POWER OFF:
Turn the motor shaft to check for jammed gear box.
If motor shaft will not turn, replace conveyor
drive(stepper) motor.
Содержание Impinger 1002
Страница 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...
Страница 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...
Страница 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...
Страница 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...
Страница 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...
Страница 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...
Страница 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...
Страница 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...
Страница 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...
Страница 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...
Страница 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...
Страница 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...
Страница 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...
Страница 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...
Страница 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...
Страница 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...
Страница 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...
Страница 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...
Страница 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...
Страница 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...
Страница 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...
Страница 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...
Страница 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...
Страница 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...
Страница 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...
Страница 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...
Страница 105: ...Impinger I 1000 Series Service Manual International 105 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE...
Страница 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...
Страница 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...
Страница 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...
Страница 112: ...Impinger I 1000 Series Service Manual International 112...