Impinger I -–1000 Series Service Manual - International
48
Spark Generator
After a pre-purge time of 30 to 60 seconds after
blower motor starts, check for 220 VAC to spark
generator. If voltage is not present, check reset
button on ignition control. If voltage is present,
visually check for spark at ignitor head.
Ignitor/Sensor Assembly
Check for visible damage to ignitor/sensor
assembly. If there is no visible damage to the
components, and no spark, replace the spark
generator. If there is visible damage to the ignitor
sensor assembly, replace. Also check for frayed or
damaged wire in burner tube.
Gas Valve
Check for 220 VAC supply to gas valve. If no
voltage present, check reset button on ignition
control, check all connections for tightness. If there
is no voltage at gas valve, replace ignition control.
If there is voltage present, check for gas pressure
at gas pressure tap located in gas piping. If there is
no gas pressure, replace gas valve.
If the ignition control is energized, and the gas
valve and ignitor circuits are energized, visually
check for pilot flame. This may be done by opening
the small inspection door on the end of the burner,
or by opening the main oven door and looking
under the lower finger housings on the right side of
the oven. If no pilot flame is visible, check the
following.
Pilot Tube
Check for gas pressure at pilot tube. Disconnect
pilot tube at burner and connect manometer to pilot
tube. If no gas pressure is present, check for
blockage in pilot tube. If these are clear, and there
is gas supplied to the oven, replace the gas valve.
Pilot Orifice
If there is gas pressure at the pilot tube, check the
pilot orifice for obstructions. Replace as needed.
No Pilot
Burner Ignitor
Check the burner ignitor head for any obstructions,
also check for frayed or broken wire, any type of
damage to spark gap (.100 in 2.5 mm).If there is
visible damage, replace ignitor assembly.
Pilot flame, but burner
will not stay ignited
Flame Sensor
(There should be a visible pilot flame at this time).
To check for flame sensor operation, connect a
digital multimeter. (Capable of measuring D.C.
microamperes) between the flame sensor wire and
the ignition control. NOTE: This is current
measurement and the meter must be connected in
series. Proper current readings should be
Honeywell 2-4 micro amp D.C., Landis & Gyr. 3
micro amp D.C. If these readings are not achieved,
replace ignitor/sensor assembly. Also check for any
type of damage to flame sensor wire and
connections.
Ignition Control
If there is sufficient flame sensor current, but the
burner will not remain ignited, check reset button on
ignition control.
Indicator light is on but
no main flame, (Model
1046-1047)
Gas Control Relay
Check for 220 VAC to relay coil. If no voltage is
present, trace wiring back to ignition control. If
voltage is present, check to insure contacts are
closing.
Содержание Impinger 1002
Страница 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...
Страница 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...
Страница 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...
Страница 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...
Страница 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...
Страница 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...
Страница 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...
Страница 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...
Страница 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...
Страница 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...
Страница 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...
Страница 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...
Страница 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...
Страница 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...
Страница 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...
Страница 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...
Страница 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...
Страница 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...
Страница 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...
Страница 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...
Страница 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...
Страница 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...
Страница 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...
Страница 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...
Страница 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...
Страница 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...
Страница 105: ...Impinger I 1000 Series Service Manual International 105 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE...
Страница 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...
Страница 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...
Страница 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...
Страница 112: ...Impinger I 1000 Series Service Manual International 112...