Lincoln Electric Statiflex 800 Скачать руководство пользователя страница 3

SECTION A:

WARNINGS

  

CALIFORNIA PROPOSITION 65 WARNINGS

WARNING: 

Breathing diesel engine exhaust

exposes you to chemicals known to the State
of California to cause cancer and birth defects,

or other reproductive harm.

• Always start and operate the engine in a 

well-ventilated area.

• If in an exposed area, vent the exhaust to the outside.
• Do not modify or tamper with the exhaust system. 
• Do not idle the engine except as necessary.

For more information go to 

www.P65 warnings.ca.gov/diesel

WARNING: This product, when used for welding or
cutting, produces fumes or gases which contain
chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California
Health & Safety Code § 25249.5 

et seq.)

WARNING: Cancer and Reproductive Harm
www.P65warnings.ca.gov

ARC WELDING CAN BE HAZARDOUS. PROTECT
YOURSELF AND OTHERS FROM POSSIBLE SERIOUS
INJURY OR DEATH. KEEP CHILDREN AWAY. 
PACEMAKER WEARERS SHOULD CONSULT WITH
THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For
additional safety information, it is strongly recommended 
that you purchase a copy of “Safety in Welding & Cutting - 
ANSI Standard Z49.1” from the American Welding Society, 
P.O. Box 351040, Miami, Florida 33135 or CSA Standard 
W117.2-1974. A Free copy of “Arc Welding Safety” booklet 
E205 is available from the Lincoln Electric Company, 
22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION,
MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE POWERED

EQUIPMENT.

   1.a. Turn the engine off before troubleshooting

and maintenance work unless the
maintenance work requires it to be running.

   1.b. Operate engines in open, well-ventilated areas or vent the engine

exhaust fumes outdoors.

   1.c. Do not add the fuel near an open flame welding

arc or when the engine is running. Stop the
engine and allow it to cool before refueling to
prevent spilled fuel from vaporizing on contact

with hot engine parts and igniting. Do not spill fuel when filling
tank. If fuel is spilled, wipe it up and do not start engine until
fumes have been eliminated.

   1.d.  Keep all equipment safety guards, covers 

and devices in position and in good repair.
Keep hands, hair, clothing and tools away 
from V-belts, gears, fans and all other 
moving parts when starting, operating or
repairing equipment.

   1.e. In some cases it may be necessary to remove safety guards to

perform required maintenance. Remove guards only when
necessary and replace them when the maintenance requiring
their removal is complete. Always use the greatest care when
working near moving parts.

   1.f.  Do not put your hands near the engine fan. Do not attempt to

override the governor or idler by pushing on the throttle control
rods while the engine is running.

   1.g. To prevent accidentally starting gasoline engines while turning

the engine or welding generator during maintenance work,
disconnect the spark plug wires, distributor cap or  magneto wire
as appropriate.

   1.h. To avoid scalding, do not remove the radiator

pressure cap when the engine is 

hot.

ELECTRIC AND

MAGNETIC FIELDS MAY

BE DANGEROUS

   2.a. Electric current flowing through any conductor

causes localized Electric and Magnetic Fields (EMF). 
Welding current creates EMF fields around welding cables 
and welding machines

   2.b. EMF fields may interfere with some pacemakers, and 

welders having a pacemaker should consult their physician
before welding.

   2.c. Exposure to EMF fields in welding may have other health effects

which are now not known.

   2.d. All welders should use the following procedures in order to

minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure

them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work

cables. If the electrode cable is on your right side, the
work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as pos-

sible to the area being welded.

2.d.5. Do not work next to welding power source.

SAFETY

Safety 02 of 04 - 5/16/2018

Содержание Statiflex 800

Страница 1: ...Filter Dual Arm 12842 w MERV 16 Filter Single Arm 12843 w MERV 16 Filter Dual Arm Save for future reference Date Purchased Code ex 10859 Serial ex U1060512345 Operator s Manual Need Help Call 1 888 93...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...hot engine parts and igniting Do not spill fuel when filling tank If fuel is spilled wipe it up and do not start engine until fumes have been eliminated 1 d Keep all equipment safety guards covers and...

Страница 4: ...m to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with s...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...d to capture welding fume at or near the arc and filter conta minants out of the air The ventilation or exhaust needed for your application depends upon many factors such as Workspace volume Workspace...

Страница 7: ...p www aws org Supplemental Information Not listed Nuisance value maximum is 10 milligrams per cubic meter PEL value for iron oxide is 10 milligrams per cubic meter TLV value for iron oxide is 5 millig...

Страница 8: ...2 MODIFICATIONS B 2 OPERATION B 2 USE B 3 FILTER MAINTENANCE INDICATOR B 3 ACCESSORIES C 1 MAINTENANCE D 1 DISPOSAL D 1 PERIODIC MAINTENANCE D 1 DISPOSAL D 3 FILTER REPLACEMENT D 3 TROUBLESHOOTING E...

Страница 9: ...CFM 1 250 M3 H STATIFLEX 800 DUAL ARM MAX 1 200 CFM 2 040 M3 H AT SIMULTANEOUS USE OF TWO SF2400 OPERATING CAPACITY EXTRACTOR TYPE LOW VACUUM HIGH VOLUME WEIGHT SINGLE ARM 270 LBS 122 KGS DUAL ARM 29...

Страница 10: ...on Arm an LFA 4 1 13 ft Extraction Arm or an LTA 2 0 Telescopic Extraction Arm to form a complete extraction system Extension cranes in 7 ft and 14 ft lengths may also be used with the wall mounted sy...

Страница 11: ...1 If parts are missing or damaged contact Lincoln Electric Automation Service 888 935 3878 UNPACKING DUAL ARM Check that the product package is complete The package should contain STATIFLEX 800 DUAL A...

Страница 12: ...cket attached to the filter unit on the back side Loosen the screws 2 places on the bottom sides and take the wall mount bracket out Do not completely remove the screws These screws are required for s...

Страница 13: ...R NON RETURN VALVE SF2400 SF4200 Mount the SF2400 fan Refer Figure A 7 and manual provided with the fan Maintain the axis alignment between the inlet of the Statiflex filter unit and outlet of the fan...

Страница 14: ...t system performance 9 Recommended Recommended ft 2 75 m 8 5 ft 2 60 m 11 in 15 5 in FIGURE A 8 DUAL ARM SETUP SF4200 EXTRACTION FANS FAN COUPLING NON RETURN VALUE HOSE CLAMP HOSE 3 OFFSET FROM THE CE...

Страница 15: ...power cord not included with the product thru the strain relief shown in Figure A 10 FIGURE A 10 The 3 conductor cable 1 conductor is a ground shall be sized for 5 amps at 115V and 25 amps at 230V The...

Страница 16: ...iring diagram on page F 1 for more details FIGURE A 11 Tightening Torque 0 6 N m 5 3 lb in Step 5 Secure the main power cord by tightening the Strain relief Step 6 Reassemble the cover plate using all...

Страница 17: ...1669 4 ARM ARM Input Power Input Power K1494 2 K1669 4 Input Power K1494 10 K1669 10 ARM ARM Input Power Input Power K1494 10 K1669 10 Input Power FIGURE A 12 ELECTRICAL CONNECTION SF2400 FIGURE A 13...

Страница 18: ...f the welding fumes are blown directly through an extraction fan into the filter Therefore never connect the Statiflex 800 to the suction opening of the extraction fan Air containing gases and particl...

Страница 19: ...its intended use and the instructions set forth in the user manual MODIFICATIONS Modifications of this product other than those specified in this manual are not allowed Modifications will void the pr...

Страница 20: ...ning The indicator slowly moves from green to red as filter cartridge becomes saturated or clogged When the Filter Maintenance Indicator is red replace the LongLife filter cartridge See Filter Replace...

Страница 21: ...2400 fan motor K1656 4 SF4200 fan motor K1669 4 Lamp Arc Sensor Kit for SF2400 fan K1669 10 Lamp Arc Sensor Kit for SF4200 fan K1494 10 starter overload switch for SF4200 fan not required if using opt...

Страница 22: ...o function with minimal maintenance In order to guarantee optimal performance level periodic maintenance and cleaning activities are required and described in this section Maintenance intervals can va...

Страница 23: ...ng a power washer X Filter Cartridges Check for damage and correct installation Replace if necessary X Dust drawers Check for damage and correct installation Replace if necessary X Empty the dust draw...

Страница 24: ...before opening the door to allow the dust in the filter compartment to settle Remove the knob item A that hold the filter retaining plates item C in place Remove the plates and then remove the used f...

Страница 25: ...For information about specific adjustments maintenance or repair jobs which are not dealt with in this manual please contact Lincoln Electric Automation Department 888 935 3878 Make sure you have the...

Страница 26: ...maged or defective Contact Lincoln Authorized Service Facility MOTOR HUMS BUT NO SUCTION Motor capacitor defective or not connected Contact Lincoln Authorized Service Facility MOTOR STOPS AUTOMATICALL...

Страница 27: ...WITCH 1 10 CABLE ASSEMBLY FRONT 1 11 CABLE ASSEMBLY TRANSFORMER 1 12 CABLE ASSEMBLY FUSE 1 13 CABLE ASSEMBLY SOLENOID 2 14 GROUND WIRE 1 15 REMOTE ASSEMBLY 1 X1 5 NOTES N A DISCONNECTING MEANS AND BRA...

Страница 28: ......

Страница 29: ......

Страница 30: ...parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa moja da l Aislese del trabajo y de la tierra...

Страница 31: ...d Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de ali mentac...

Страница 32: ...advice once it has been given nor does the provision of information or advice create expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive manufacturer...

Отзывы: