Lincoln Electric Statiflex 800 Скачать руководство пользователя страница 19

B-2

OPERATION

STATIFLEX

®

800

Only use the product for 

light to medium duty 

extraction and filtration of welding fume

Avoid using the product for

 

extracting and/or 

filtering fumes and gases which are

 

released during 

the following processes:

oxy-fuel cutting

aluminum laser cutting

oil-treated metal

arc-air gouging

oil mist

paint mist

heavy oil mist in welding fume

hot gases (more than 40°C/100°F continuously)

aggressive gases (e.g. from acids)

plasma cutting

grinding aluminum and magnesium

flame spraying

extraction of cement, saw dust, wood dust etc.

sucking cigarettes, cigars, oiled tissues and other
burning particles, objects and acids

 in all situations where explosions can occur

(This list is not comprehensive.)

If the product is used in above situations it could result in
potential fire hazard, non-compliance with local
regulations and reduction in product performance and
life.

USERS

This product should only be used by authorized, trained and
qualified users.

INTENDED USE

The product has been designed exclusively for filtering fume
which is released during common weld processes. Using the
product for other purposes is considered contrary to its intended
use. Lincoln Electric accepts no liability for any damage resulting
from such use. Only use the product in mechanically sound
condition in accordance with its intended use and the instructions
set forth in the user manual.

MODIFICATIONS

Modifications of this product, other than those specified in this
manual, are not allowed. Modifications will void the product
warranty.

OPERATION

The operation description below applies to all versions of the base
unit. The air which contains welding fume is captured, extracted
and filtered, in which the filtered air can be either recirculated or
exhausted.

First, the welding fume is extracted through one or two

 

adjustable

fume extraction arm(s) by one or two external

 

extraction fan(s).

Second, the fan unit(s) exhaust(s) the welding fume via a hose or
duct into the Statiflex filter unit.

Third, as the welding fume enters the Statiflex unit, it passes
through the prefilter. The prefilter separates larger particles,
debris and sparks prior to the welding fume entering the

 

LongLife

filter.

Fourth, the welding fume passes through the LongLife filter
cartridge (stabilized).

Fifth, after passing through the LongLife filter, the filtered air

 

exits

the Statiflex via the outlet opening(s) at top of unit.

The filter cleaning system inside the Statiflex starts automatically
when the pressure drop reaches a certain maximum value during
use. The filter cartridges are cleaned from the inside by
compressed air pulses. An integrated 

alarm lamp

 indicates when

the

 

filter cartridges need to be replaced. Pressing the Manual

clean

 

button activates the cleaning cycles. It will pulse a total of

10

 

times, 5 pulses on each filter

 - refer to figure B.2.

WARNING

Содержание Statiflex 800

Страница 1: ...Filter Dual Arm 12842 w MERV 16 Filter Single Arm 12843 w MERV 16 Filter Dual Arm Save for future reference Date Purchased Code ex 10859 Serial ex U1060512345 Operator s Manual Need Help Call 1 888 93...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...hot engine parts and igniting Do not spill fuel when filling tank If fuel is spilled wipe it up and do not start engine until fumes have been eliminated 1 d Keep all equipment safety guards covers and...

Страница 4: ...m to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with s...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...d to capture welding fume at or near the arc and filter conta minants out of the air The ventilation or exhaust needed for your application depends upon many factors such as Workspace volume Workspace...

Страница 7: ...p www aws org Supplemental Information Not listed Nuisance value maximum is 10 milligrams per cubic meter PEL value for iron oxide is 10 milligrams per cubic meter TLV value for iron oxide is 5 millig...

Страница 8: ...2 MODIFICATIONS B 2 OPERATION B 2 USE B 3 FILTER MAINTENANCE INDICATOR B 3 ACCESSORIES C 1 MAINTENANCE D 1 DISPOSAL D 1 PERIODIC MAINTENANCE D 1 DISPOSAL D 3 FILTER REPLACEMENT D 3 TROUBLESHOOTING E...

Страница 9: ...CFM 1 250 M3 H STATIFLEX 800 DUAL ARM MAX 1 200 CFM 2 040 M3 H AT SIMULTANEOUS USE OF TWO SF2400 OPERATING CAPACITY EXTRACTOR TYPE LOW VACUUM HIGH VOLUME WEIGHT SINGLE ARM 270 LBS 122 KGS DUAL ARM 29...

Страница 10: ...on Arm an LFA 4 1 13 ft Extraction Arm or an LTA 2 0 Telescopic Extraction Arm to form a complete extraction system Extension cranes in 7 ft and 14 ft lengths may also be used with the wall mounted sy...

Страница 11: ...1 If parts are missing or damaged contact Lincoln Electric Automation Service 888 935 3878 UNPACKING DUAL ARM Check that the product package is complete The package should contain STATIFLEX 800 DUAL A...

Страница 12: ...cket attached to the filter unit on the back side Loosen the screws 2 places on the bottom sides and take the wall mount bracket out Do not completely remove the screws These screws are required for s...

Страница 13: ...R NON RETURN VALVE SF2400 SF4200 Mount the SF2400 fan Refer Figure A 7 and manual provided with the fan Maintain the axis alignment between the inlet of the Statiflex filter unit and outlet of the fan...

Страница 14: ...t system performance 9 Recommended Recommended ft 2 75 m 8 5 ft 2 60 m 11 in 15 5 in FIGURE A 8 DUAL ARM SETUP SF4200 EXTRACTION FANS FAN COUPLING NON RETURN VALUE HOSE CLAMP HOSE 3 OFFSET FROM THE CE...

Страница 15: ...power cord not included with the product thru the strain relief shown in Figure A 10 FIGURE A 10 The 3 conductor cable 1 conductor is a ground shall be sized for 5 amps at 115V and 25 amps at 230V The...

Страница 16: ...iring diagram on page F 1 for more details FIGURE A 11 Tightening Torque 0 6 N m 5 3 lb in Step 5 Secure the main power cord by tightening the Strain relief Step 6 Reassemble the cover plate using all...

Страница 17: ...1669 4 ARM ARM Input Power Input Power K1494 2 K1669 4 Input Power K1494 10 K1669 10 ARM ARM Input Power Input Power K1494 10 K1669 10 Input Power FIGURE A 12 ELECTRICAL CONNECTION SF2400 FIGURE A 13...

Страница 18: ...f the welding fumes are blown directly through an extraction fan into the filter Therefore never connect the Statiflex 800 to the suction opening of the extraction fan Air containing gases and particl...

Страница 19: ...its intended use and the instructions set forth in the user manual MODIFICATIONS Modifications of this product other than those specified in this manual are not allowed Modifications will void the pr...

Страница 20: ...ning The indicator slowly moves from green to red as filter cartridge becomes saturated or clogged When the Filter Maintenance Indicator is red replace the LongLife filter cartridge See Filter Replace...

Страница 21: ...2400 fan motor K1656 4 SF4200 fan motor K1669 4 Lamp Arc Sensor Kit for SF2400 fan K1669 10 Lamp Arc Sensor Kit for SF4200 fan K1494 10 starter overload switch for SF4200 fan not required if using opt...

Страница 22: ...o function with minimal maintenance In order to guarantee optimal performance level periodic maintenance and cleaning activities are required and described in this section Maintenance intervals can va...

Страница 23: ...ng a power washer X Filter Cartridges Check for damage and correct installation Replace if necessary X Dust drawers Check for damage and correct installation Replace if necessary X Empty the dust draw...

Страница 24: ...before opening the door to allow the dust in the filter compartment to settle Remove the knob item A that hold the filter retaining plates item C in place Remove the plates and then remove the used f...

Страница 25: ...For information about specific adjustments maintenance or repair jobs which are not dealt with in this manual please contact Lincoln Electric Automation Department 888 935 3878 Make sure you have the...

Страница 26: ...maged or defective Contact Lincoln Authorized Service Facility MOTOR HUMS BUT NO SUCTION Motor capacitor defective or not connected Contact Lincoln Authorized Service Facility MOTOR STOPS AUTOMATICALL...

Страница 27: ...WITCH 1 10 CABLE ASSEMBLY FRONT 1 11 CABLE ASSEMBLY TRANSFORMER 1 12 CABLE ASSEMBLY FUSE 1 13 CABLE ASSEMBLY SOLENOID 2 14 GROUND WIRE 1 15 REMOTE ASSEMBLY 1 X1 5 NOTES N A DISCONNECTING MEANS AND BRA...

Страница 28: ......

Страница 29: ......

Страница 30: ...parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa moja da l Aislese del trabajo y de la tierra...

Страница 31: ...d Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de ali mentac...

Страница 32: ...advice once it has been given nor does the provision of information or advice create expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive manufacturer...

Отзывы: