OPERATION
STATIFLEX
®
800
Only use the product for
light to medium duty
extraction and filtration of welding fume
.
Avoid using the product for
extracting and/or
filtering fumes and gases which are
released during
the following processes:
•
oxy-fuel cutting
•
aluminum laser cutting
•
oil-treated metal
•
arc-air gouging
•
oil mist
•
paint mist
•
heavy oil mist in welding fume
•
hot gases (more than 40°C/100°F continuously)
•
aggressive gases (e.g. from acids)
•
plasma cutting
•
grinding aluminum and magnesium
•
flame spraying
•
extraction of cement, saw dust, wood dust etc.
•
sucking cigarettes, cigars, oiled tissues and other
burning particles, objects and acids
•
in all situations where explosions can occur
(This list is not comprehensive.)
If the product is used in above situations it could result in
potential fire hazard, non-compliance with local
regulations and reduction in product performance and
life.
USERS
This product should only be used by authorized, trained and
qualified users.
INTENDED USE
The product has been designed exclusively for filtering fume
which is released during common weld processes. Using the
product for other purposes is considered contrary to its intended
use. Lincoln Electric accepts no liability for any damage resulting
from such use. Only use the product in mechanically sound
condition in accordance with its intended use and the instructions
set forth in the user manual.
MODIFICATIONS
Modifications of this product, other than those specified in this
manual, are not allowed. Modifications will void the product
warranty.
OPERATION
The operation description below applies to all versions of the base
unit. The air which contains welding fume is captured, extracted
and filtered, in which the filtered air can be either recirculated or
exhausted.
•
First, the welding fume is extracted through one or two
adjustable
fume extraction arm(s) by one or two external
extraction fan(s).
•
Second, the fan unit(s) exhaust(s) the welding fume via a hose or
duct into the Statiflex filter unit.
•
Third, as the welding fume enters the Statiflex unit, it passes
through the prefilter. The prefilter separates larger particles,
debris and sparks prior to the welding fume entering the
LongLife
filter.
•
Fourth, the welding fume passes through the LongLife filter
cartridge (stabilized).
•
Fifth, after passing through the LongLife filter, the filtered air
exits
the Statiflex via the outlet opening(s) at top of unit.
•
The filter cleaning system inside the Statiflex starts automatically
when the pressure drop reaches a certain maximum value during
use. The filter cartridges are cleaned from the inside by
compressed air pulses. An integrated
alarm lamp
indicates when
the
filter cartridges need to be replaced. Pressing the Manual
clean
button activates the cleaning cycles. It will pulse a total of
10
times, 5 pulses on each filter
- refer to figure B.2.
WARNING