INSTALLATION
STATIFLEX
®
800
GENERAL DESCRIPTION
The Statiflex 800 Wall-Mounted Filter Unit provides efficient
filtration for use with a Lincoln SF2400 Stationary Fan and LFA
3.1/4.1 or LTA 2.0 Arms. The Statiflex 800 features a spark
arrester and a paper filter cartridge with a filtration efficiency of
99.8%.
The Statiflex 800 uses an automatic filter cleaning system to
maintain the filter and reduce maintenance costs. Fume collected
on the outside of the filter is knocked off by a blast of compressed
air from the cleaning system. Fume then drops into the dust
collection
tray inside
the unit.
When the pressure drop across the filter reaches a set point due
to an increase in fume on the outside of the filter, a solenoid
releases air from a compressed air rese
r
voir tank mounted inside
the filter cartridge. This air goes through several holes in the
cleaning tube, cleaning one section of the filter with multiple air
jets. The cleaning tube then shifts to the next section of the filter
until the pressure drop again reaches the set point, triggering the
next cleaning pulse.
A manual cleaning cycle is initiated by pressing the
S
tart
button on
the face of the machine. The system pauses between
pulses
,
allowing the air tank to repressurize. The
Statiflex 800 requires
70-120
psi of clean, dry compressed air to
function properly.
The Statiflex 800 Filter Unit and SF2400 Stationary Fan can be
combined with an LFA 3.1, 10 ft. Extraction Arm, an LFA 4.1, 13
ft.
Extraction Arm, or an LTA 2.0 Telescopic Extraction Arm to form
a
complete extraction system. Extension cranes in 7 ft. and 14 ft.
lengths may also be used with the wall-mounted system
including
Statiflex 800 Filter.
A Starter/Overload Switch or Lamp Kit for Wall-Mounted Systems
must be included with any wall-mounted extraction system to
power the SF2400 Fan
Lamp Kits for wall mounted systems, either with or without
automatic start/stop arc sensor, are available with capabilities of
starting and stopping the SF2400 fan from a remote switch at the
end of the arm.
24V AC powers the PC board for the cleaning
system inside the
Statiflex 800 unit
.
Available Equipment:
In order to operate the Statiflex 800 system, selection of following
products is required:
•
K1656-9 SF2400 extraction fan required
•
K1655-8 LFA 3.1 10 ft. extraction arm; or
•
K1655-9 LFA 4.1 13 ft. extraction arm; or
•
K1655-12 LFA 2.0 6.5 ft. extraction arm; or
•
K1655-13 LFA 4.1-LC 13 ft. Low Ceiling extraction arm; or
•
K1655-10 LTA 2.0 telescopic extraction arm; or
•
K1655-14 LTA 2.0-CW telescopic extraction arm required*
•
K1494-2 (2) starter/overload switch for SF2400 fan (not required
if using optional K1669-4 Lamp Kit with Arc Sensor)
•
K1494-10 starter/overload switch for SF4200 fan (K1656-4)
•
K1657-1 (2) Mounting Bracket (for LFA 3.1 and 4.1 extraction
arms); or
•
K1657-2 (2) Mounting Bracket (for LFA 2.0. LTA 2.0 and LFA
4.1-LC extraction arms)
•
K1671-1 Extension Crane (7 ft) and K1671-2 Extension Crane
(14 ft)
*
Depending on specific application and work requirements,
various combinations of extraction arms can be used -e.g. (1)
K1655-9 LFA 3.1 arm and (1) K1655-10 LFA 2.0 arm.