A-2

INSTALLATION

STATIFLEX

®

800

GENERAL DESCRIPTION

The Statiflex 800 Wall-Mounted Filter Unit provides efficient

 

filtration for use with a Lincoln SF2400 Stationary Fan and LFA

 

3.1/4.1 or LTA 2.0 Arms. The Statiflex 800 features a spark

 

arrester and a paper filter cartridge with a filtration efficiency of

 

99.8%. 

The Statiflex 800 uses an automatic filter cleaning system to

 

maintain the filter and reduce maintenance costs. Fume collected

 

on the outside of the filter is knocked off by a blast of compressed

 

air from the cleaning system. Fume then drops into the dust

 

collection 

tray inside 

the unit.

When the pressure drop across the filter reaches a set point due

 

to an increase in fume on the outside of the filter, a solenoid

 

releases air from a compressed air rese

r

voir tank mounted inside

 

the filter cartridge. This air goes through several holes in the

 

cleaning tube, cleaning one section of the filter with multiple air

 

jets. The cleaning tube then shifts to the next section of the filter

 

until the pressure drop again reaches the set point, triggering the

 

next cleaning pulse.

A manual cleaning cycle is initiated by pressing the 

S

tart

 

button on 

the face of the machine. The system pauses between

 

pulses

allowing the air tank to repressurize. The

 

Statiflex 800 requires 

70-120

 psi of clean, dry compressed air to

 

function properly.

The Statiflex 800 Filter Unit and SF2400 Stationary Fan can be

 

combined with an LFA 3.1, 10 ft. Extraction Arm, an LFA 4.1, 13

 

ft. 

Extraction Arm, or an LTA 2.0 Telescopic Extraction Arm to form

 

complete extraction system. Extension cranes in 7 ft. and 14 ft.

 

lengths may also be used  with the wall-mounted system

 

including 

Statiflex 800 Filter.

A Starter/Overload Switch or Lamp Kit for Wall-Mounted Systems

 

must be included with any wall-mounted extraction system to

 

power the SF2400 Fan

Lamp Kits for wall mounted systems, either with or without

 

automatic start/stop arc sensor, are available with capabilities of

 

starting and stopping the SF2400 fan from a remote switch at the

 

end of the arm.

24V AC powers the PC board for the cleaning 

system inside the 

Statiflex 800 unit

Available Equipment:

In order to operate the Statiflex 800 system, selection of following
products is required:

K1656-9 SF2400 extraction fan required

K1655-8 LFA 3.1 10 ft. extraction arm; or

K1655-9 LFA 4.1 13 ft. extraction arm; or

K1655-12 LFA 2.0 6.5 ft. extraction arm; or

K1655-13 LFA 4.1-LC 13 ft. Low Ceiling extraction arm; or

K1655-10 LTA 2.0 telescopic extraction arm; or

K1655-14 LTA 2.0-CW telescopic extraction arm required*

K1494-2 (2) starter/overload switch for SF2400 fan (not required
if using optional K1669-4 Lamp Kit with Arc Sensor)

K1494-10 starter/overload switch for SF4200 fan (K1656-4)

K1657-1 (2) Mounting Bracket (for LFA 3.1 and 4.1 extraction
arms); or

K1657-2 (2) Mounting Bracket (for LFA 2.0. LTA 2.0 and LFA
4.1-LC extraction arms)

K1671-1 Extension Crane (7 ft)  and K1671-2 Extension Crane

(14 ft)

*

Depending on specific application and work requirements,

various combinations of extraction arms can be used -e.g. (1)
K1655-9 LFA 3.1 arm and (1) K1655-10 LFA 2.0 arm.

Содержание Statiflex 800

Страница 1: ...Filter Dual Arm 12842 w MERV 16 Filter Single Arm 12843 w MERV 16 Filter Dual Arm Save for future reference Date Purchased Code ex 10859 Serial ex U1060512345 Operator s Manual Need Help Call 1 888 93...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...hot engine parts and igniting Do not spill fuel when filling tank If fuel is spilled wipe it up and do not start engine until fumes have been eliminated 1 d Keep all equipment safety guards covers and...

Страница 4: ...m to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with s...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...d to capture welding fume at or near the arc and filter conta minants out of the air The ventilation or exhaust needed for your application depends upon many factors such as Workspace volume Workspace...

Страница 7: ...p www aws org Supplemental Information Not listed Nuisance value maximum is 10 milligrams per cubic meter PEL value for iron oxide is 10 milligrams per cubic meter TLV value for iron oxide is 5 millig...

Страница 8: ...2 MODIFICATIONS B 2 OPERATION B 2 USE B 3 FILTER MAINTENANCE INDICATOR B 3 ACCESSORIES C 1 MAINTENANCE D 1 DISPOSAL D 1 PERIODIC MAINTENANCE D 1 DISPOSAL D 3 FILTER REPLACEMENT D 3 TROUBLESHOOTING E...

Страница 9: ...CFM 1 250 M3 H STATIFLEX 800 DUAL ARM MAX 1 200 CFM 2 040 M3 H AT SIMULTANEOUS USE OF TWO SF2400 OPERATING CAPACITY EXTRACTOR TYPE LOW VACUUM HIGH VOLUME WEIGHT SINGLE ARM 270 LBS 122 KGS DUAL ARM 29...

Страница 10: ...on Arm an LFA 4 1 13 ft Extraction Arm or an LTA 2 0 Telescopic Extraction Arm to form a complete extraction system Extension cranes in 7 ft and 14 ft lengths may also be used with the wall mounted sy...

Страница 11: ...1 If parts are missing or damaged contact Lincoln Electric Automation Service 888 935 3878 UNPACKING DUAL ARM Check that the product package is complete The package should contain STATIFLEX 800 DUAL A...

Страница 12: ...cket attached to the filter unit on the back side Loosen the screws 2 places on the bottom sides and take the wall mount bracket out Do not completely remove the screws These screws are required for s...

Страница 13: ...R NON RETURN VALVE SF2400 SF4200 Mount the SF2400 fan Refer Figure A 7 and manual provided with the fan Maintain the axis alignment between the inlet of the Statiflex filter unit and outlet of the fan...

Страница 14: ...t system performance 9 Recommended Recommended ft 2 75 m 8 5 ft 2 60 m 11 in 15 5 in FIGURE A 8 DUAL ARM SETUP SF4200 EXTRACTION FANS FAN COUPLING NON RETURN VALUE HOSE CLAMP HOSE 3 OFFSET FROM THE CE...

Страница 15: ...power cord not included with the product thru the strain relief shown in Figure A 10 FIGURE A 10 The 3 conductor cable 1 conductor is a ground shall be sized for 5 amps at 115V and 25 amps at 230V The...

Страница 16: ...iring diagram on page F 1 for more details FIGURE A 11 Tightening Torque 0 6 N m 5 3 lb in Step 5 Secure the main power cord by tightening the Strain relief Step 6 Reassemble the cover plate using all...

Страница 17: ...1669 4 ARM ARM Input Power Input Power K1494 2 K1669 4 Input Power K1494 10 K1669 10 ARM ARM Input Power Input Power K1494 10 K1669 10 Input Power FIGURE A 12 ELECTRICAL CONNECTION SF2400 FIGURE A 13...

Страница 18: ...f the welding fumes are blown directly through an extraction fan into the filter Therefore never connect the Statiflex 800 to the suction opening of the extraction fan Air containing gases and particl...

Страница 19: ...its intended use and the instructions set forth in the user manual MODIFICATIONS Modifications of this product other than those specified in this manual are not allowed Modifications will void the pr...

Страница 20: ...ning The indicator slowly moves from green to red as filter cartridge becomes saturated or clogged When the Filter Maintenance Indicator is red replace the LongLife filter cartridge See Filter Replace...

Страница 21: ...2400 fan motor K1656 4 SF4200 fan motor K1669 4 Lamp Arc Sensor Kit for SF2400 fan K1669 10 Lamp Arc Sensor Kit for SF4200 fan K1494 10 starter overload switch for SF4200 fan not required if using opt...

Страница 22: ...o function with minimal maintenance In order to guarantee optimal performance level periodic maintenance and cleaning activities are required and described in this section Maintenance intervals can va...

Страница 23: ...ng a power washer X Filter Cartridges Check for damage and correct installation Replace if necessary X Dust drawers Check for damage and correct installation Replace if necessary X Empty the dust draw...

Страница 24: ...before opening the door to allow the dust in the filter compartment to settle Remove the knob item A that hold the filter retaining plates item C in place Remove the plates and then remove the used f...

Страница 25: ...For information about specific adjustments maintenance or repair jobs which are not dealt with in this manual please contact Lincoln Electric Automation Department 888 935 3878 Make sure you have the...

Страница 26: ...maged or defective Contact Lincoln Authorized Service Facility MOTOR HUMS BUT NO SUCTION Motor capacitor defective or not connected Contact Lincoln Authorized Service Facility MOTOR STOPS AUTOMATICALL...

Страница 27: ...WITCH 1 10 CABLE ASSEMBLY FRONT 1 11 CABLE ASSEMBLY TRANSFORMER 1 12 CABLE ASSEMBLY FUSE 1 13 CABLE ASSEMBLY SOLENOID 2 14 GROUND WIRE 1 15 REMOTE ASSEMBLY 1 X1 5 NOTES N A DISCONNECTING MEANS AND BRA...

Страница 28: ......

Страница 29: ......

Страница 30: ...parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa moja da l Aislese del trabajo y de la tierra...

Страница 31: ...d Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de ali mentac...

Страница 32: ...advice once it has been given nor does the provision of information or advice create expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive manufacturer...

Отзывы: