Lincoln Electric Statiflex 800 Скачать руководство пользователя страница 2

THANK YOU FOR SELECTING 

A QUALITY PRODUCT BY 

LINCOLN  ELEC  TRIC. 

PLEASE EXAMINE CARTON AND EQUIPMENT FOR
DAMAGE IMMEDIATELY

When this equipment is shipped, title passes to the purchaser
upon receipt by the carrier. Consequently, claims for material
damaged in shipment must be made by the purchaser against the
transportation company at the time the shipment is received.

SAFETY DEPENDS ON YOU

Lincoln arc welding and cutting equipment is designed and built
with safety in mind. However, your overall safety can be increased
by proper installation ... and thoughtful operation on your part. 

DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT 

WITHOUT READING THIS MANUAL AND THE SAFETY

PRECAUTIONS CONTAINED THROUGHOUT.

And, most importantly,

think before you act and be careful.

This statement appears where the information must be followed
exactly to avoid serious personal injury or loss of life.

This statement appears where the information must be followed
to avoid minor personal injury or damage to this equipment.

KEEP YOUR HEAD OUT OF THE FUMES.

DON’T

get too close to the arc.

Use corrective lenses if necessary
to stay a reasonable distance
away from the arc.

READ

and obey the Safety Data

Sheet (SDS) and the warning label
that appears on all containers of
welding materials.

USE ENOUGH VENTILATION

or

exhaust at the arc, or both, to
keep the fumes and gases from 
your breathing zone and the general area.

IN A LARGE ROOM OR OUTDOORS

, natural ventilation may be

adequate if you keep your head out of the fumes (See below).

USE NATURAL DRAFTS

or fans to keep the fumes away 

from your face.

If you de velop unusual symptoms, see your supervisor. 
Perhaps the welding atmosphere and ventilation system 
should be checked.

WEAR CORRECT EYE, EAR & 
BODY PROTECTION

PROTECT

your eyes and face with welding helmet

properly fitted and with proper grade of filter plate
(See ANSI Z49.1).

PROTECT

your body from welding spatter and arc

flash with protective clothing including woolen
clothing, flame-proof apron and gloves, leather
leggings, and high boots.

PROTECT

others from splatter, flash, and glare

with protective screens or barriers.

IN SOME AREAS

, protection from noise may be appropriate.

BE SURE

protective equipment is in good condition.

Also, wear safety glasses in work area

AT ALL TIMES.

SPECIAL SITUATIONS

DO NOT WELD OR CUT

containers or materials which previously

had been in contact with hazardous substances unless they are
properly cleaned. This is extremely dangerous.

DO NOT WELD OR CUT

painted or plated parts unless special

precautions with ventilation have been taken. They can release
highly toxic fumes or gases.

Additional precautionary measures

PROTECT

compressed gas cylinders from excessive heat,

mechanical shocks, and arcs; fasten cylinders so they cannot fall.

BE SURE

cylinders are never grounded or part of an 

electrical circuit.

REMOVE 

all potential fire hazards from welding area.

ALWAYS HAVE FIRE FIGHTING EQUIPMENT READY FOR

IMMEDIATE USE AND KNOW HOW TO USE IT.

WARNING

CAUTION

Safety 01 of 04 - 5/16/2018

Содержание Statiflex 800

Страница 1: ...Filter Dual Arm 12842 w MERV 16 Filter Single Arm 12843 w MERV 16 Filter Dual Arm Save for future reference Date Purchased Code ex 10859 Serial ex U1060512345 Operator s Manual Need Help Call 1 888 93...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...hot engine parts and igniting Do not spill fuel when filling tank If fuel is spilled wipe it up and do not start engine until fumes have been eliminated 1 d Keep all equipment safety guards covers and...

Страница 4: ...m to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with s...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...d to capture welding fume at or near the arc and filter conta minants out of the air The ventilation or exhaust needed for your application depends upon many factors such as Workspace volume Workspace...

Страница 7: ...p www aws org Supplemental Information Not listed Nuisance value maximum is 10 milligrams per cubic meter PEL value for iron oxide is 10 milligrams per cubic meter TLV value for iron oxide is 5 millig...

Страница 8: ...2 MODIFICATIONS B 2 OPERATION B 2 USE B 3 FILTER MAINTENANCE INDICATOR B 3 ACCESSORIES C 1 MAINTENANCE D 1 DISPOSAL D 1 PERIODIC MAINTENANCE D 1 DISPOSAL D 3 FILTER REPLACEMENT D 3 TROUBLESHOOTING E...

Страница 9: ...CFM 1 250 M3 H STATIFLEX 800 DUAL ARM MAX 1 200 CFM 2 040 M3 H AT SIMULTANEOUS USE OF TWO SF2400 OPERATING CAPACITY EXTRACTOR TYPE LOW VACUUM HIGH VOLUME WEIGHT SINGLE ARM 270 LBS 122 KGS DUAL ARM 29...

Страница 10: ...on Arm an LFA 4 1 13 ft Extraction Arm or an LTA 2 0 Telescopic Extraction Arm to form a complete extraction system Extension cranes in 7 ft and 14 ft lengths may also be used with the wall mounted sy...

Страница 11: ...1 If parts are missing or damaged contact Lincoln Electric Automation Service 888 935 3878 UNPACKING DUAL ARM Check that the product package is complete The package should contain STATIFLEX 800 DUAL A...

Страница 12: ...cket attached to the filter unit on the back side Loosen the screws 2 places on the bottom sides and take the wall mount bracket out Do not completely remove the screws These screws are required for s...

Страница 13: ...R NON RETURN VALVE SF2400 SF4200 Mount the SF2400 fan Refer Figure A 7 and manual provided with the fan Maintain the axis alignment between the inlet of the Statiflex filter unit and outlet of the fan...

Страница 14: ...t system performance 9 Recommended Recommended ft 2 75 m 8 5 ft 2 60 m 11 in 15 5 in FIGURE A 8 DUAL ARM SETUP SF4200 EXTRACTION FANS FAN COUPLING NON RETURN VALUE HOSE CLAMP HOSE 3 OFFSET FROM THE CE...

Страница 15: ...power cord not included with the product thru the strain relief shown in Figure A 10 FIGURE A 10 The 3 conductor cable 1 conductor is a ground shall be sized for 5 amps at 115V and 25 amps at 230V The...

Страница 16: ...iring diagram on page F 1 for more details FIGURE A 11 Tightening Torque 0 6 N m 5 3 lb in Step 5 Secure the main power cord by tightening the Strain relief Step 6 Reassemble the cover plate using all...

Страница 17: ...1669 4 ARM ARM Input Power Input Power K1494 2 K1669 4 Input Power K1494 10 K1669 10 ARM ARM Input Power Input Power K1494 10 K1669 10 Input Power FIGURE A 12 ELECTRICAL CONNECTION SF2400 FIGURE A 13...

Страница 18: ...f the welding fumes are blown directly through an extraction fan into the filter Therefore never connect the Statiflex 800 to the suction opening of the extraction fan Air containing gases and particl...

Страница 19: ...its intended use and the instructions set forth in the user manual MODIFICATIONS Modifications of this product other than those specified in this manual are not allowed Modifications will void the pr...

Страница 20: ...ning The indicator slowly moves from green to red as filter cartridge becomes saturated or clogged When the Filter Maintenance Indicator is red replace the LongLife filter cartridge See Filter Replace...

Страница 21: ...2400 fan motor K1656 4 SF4200 fan motor K1669 4 Lamp Arc Sensor Kit for SF2400 fan K1669 10 Lamp Arc Sensor Kit for SF4200 fan K1494 10 starter overload switch for SF4200 fan not required if using opt...

Страница 22: ...o function with minimal maintenance In order to guarantee optimal performance level periodic maintenance and cleaning activities are required and described in this section Maintenance intervals can va...

Страница 23: ...ng a power washer X Filter Cartridges Check for damage and correct installation Replace if necessary X Dust drawers Check for damage and correct installation Replace if necessary X Empty the dust draw...

Страница 24: ...before opening the door to allow the dust in the filter compartment to settle Remove the knob item A that hold the filter retaining plates item C in place Remove the plates and then remove the used f...

Страница 25: ...For information about specific adjustments maintenance or repair jobs which are not dealt with in this manual please contact Lincoln Electric Automation Department 888 935 3878 Make sure you have the...

Страница 26: ...maged or defective Contact Lincoln Authorized Service Facility MOTOR HUMS BUT NO SUCTION Motor capacitor defective or not connected Contact Lincoln Authorized Service Facility MOTOR STOPS AUTOMATICALL...

Страница 27: ...WITCH 1 10 CABLE ASSEMBLY FRONT 1 11 CABLE ASSEMBLY TRANSFORMER 1 12 CABLE ASSEMBLY FUSE 1 13 CABLE ASSEMBLY SOLENOID 2 14 GROUND WIRE 1 15 REMOTE ASSEMBLY 1 X1 5 NOTES N A DISCONNECTING MEANS AND BRA...

Страница 28: ......

Страница 29: ......

Страница 30: ...parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa moja da l Aislese del trabajo y de la tierra...

Страница 31: ...d Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de ali mentac...

Страница 32: ...advice once it has been given nor does the provision of information or advice create expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive manufacturer...

Отзывы: