A-7
INSTALLATION
STATIFLEX
®
800
ELECTRICAL CONNECTION
ELECTRIC SHOCK can kill.
•
DISCONNECT FROM SUPPLY CIRCUIT
BEFORE OPENING THE ACCESS DOOR
•
Only qualified personnel should install,
use, or service this equipment.
•
Do not operate with covers, panels, or
guards removed.
Step : 1
Remove the two screws and open the access door. Refer
to
Figure
A.8.
FIGURE A.8
Step : 2
Remove the four screws that hold the cover plate and
remove
the
cover plate. Refer
to
Figure A.9
.
FIGURE A.9
Step : 3
Route the main power cord (not included with the product) thru
the strain relief shown in Figure A.10.
FIGURE A.10
The 3 conductor cable (1 conductor is a ground) shall be sized
for .5 amps at 115V and .25 amps at 230V. The minimum wire
type should be SOOW 18AWG cable with a maximum 1/2" OD.
This cable only powers the Statiflex 800 controls and filter
cleaning. It does not power the SF2400 or SF4200 fan motors or
controls. See figures A.12 and A.13 for an overview of the entire
system electrical connections. Refer to the installation section of
the fans, controls and extraction arms operators manuals.
WARNING
INPUT VOLTAGE
1 ~ 60 HZ
1 ~ 50/60 HZ
115 V
230 V
0.5 A
0.25 A
Access Door
Cover Plate
Strain Relief