![Lincoln Electric Statiflex 800 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/lincoln-electric/statiflex-800/statiflex-800_operators-manual_1918353026.webp)
E-2
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
STATIFLEX
®
800
PROBLEMS / SYMPTOM(S)
POSSIBLE CAUSE(S)
RECOMMENDED COURSE(S) OF ACTION
MOTOR DOES NOT START.
No input power.
Verify 120VAC/60Hz, 1ph or 230VAC/50/60Hz, 1ph input power
at the machine
Input cord maybe damaged.
Check the integrity of the input cord
Loose Contacts
Check the contacts.
Starter/overload switch
damaged or defective.
Contact Lincoln Authorized Service Facility
Motor maybe damaged or
defective.
Contact Lincoln Authorized Service Facility
MOTOR HUMS, BUT NO
SUCTION.
Motor capacitor defective or not
connected.
Contact Lincoln Authorized Service Facility
MOTOR STOPS
AUTOMATICALLY
Motor overload protection
activated.
Let the machine cool down for a few minutes.
Motor defective or damaged
Contact Lincoln Authorized Service Facility
POOR SUCTION.
Leakage.
Check hose connections and integrity.
Outlet grid blocked.
Remove obstructions from outlet grid.
Air path in arm blocked.
Remove obstructions from arm.
Filter blocked (check
Maintenance Indicator).
Replace filter.
Spark arrester blocked.
Clean the spark arrester.
Blower fan blocked.
Clean excess fume or spatter from fan.
Fan seal damaged.
Check or replace sealing material of fan.
DUST OR SMOKE COMING OUT
OF OUTLET.
Filter damaged, or not seated
correctly.
Replace the filter or reseat it.
VIBRATIONS IN THE MACHINE.
Imbalance in the fan.
Clean excess dirt from fan.