Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
TROUBLESHOOTING & REPAIR
F-33
F-33
SQUARE WAVE TIG 275
This is the typical AC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 2 milliseconds in time.
NOTE: Scope probes connected at
machine output terminals: (+) probe to
electrode, (–) probe to work.
NOTE: AC balance control set at
“Balanced” position.
SCOPE SETTINGS
Volts/Div....................50 V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
AC TIG MODE
0 V
50 V
2 ms
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
• Perform High Frequency Disable Procedure.