TROUBLESHOOTING & REPAIR
F-23
F-23
SQUARE WAVE TIG 275
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
T1 MAIN TRANSFORMER TEST
(continued)
TABLE F.1.
T1 TRANSFORMER VOLTAGES
TEST POINTS
ACCEPTABLE VOLTAGES
SECONDARY WINDINGS
SECONDARY VOLTAGES
PLUG J8 PIN 1 (LEAD #210)
TO
PLUG J8 PIN 9 (LEAD #209)
18 VAC
PLUG J8 PIN 6 (LEAD #201)
TO
PLUG J8 PIN 4 (LEAD #204)
18 VAC
PLUG J8 PIN 2 (LEAD #231)
TO
PLUG J8 PIN 12 (LEAD #232A)
115 VAC
PLUG J8 PIN 13 (LEAD #211A)
TO
PLUG J8 PIN 14 (LEAD #212)
23 VAC
X1 TO X2
78 VAC
PRIMARY WINDINGS
1
PRIMARY VOLTAGES
H1 TO H2
208 VAC
H1 TO H3
230 VAC
H1 TO H4
460 VAC
NOTE: If the input voltages vary, the secondary voltages will vary accordingly.
1
Based on 208/230/460 models. For other voltage models refer to appropriate wiring diagram.