TROUBLESHOOTING & REPAIR
F-41
F-41
SQUARE WAVE TIG 275
This is NOT the typical DC (+) output
voltage waveform. One output SCR is
not functioning. Note the “gap” in the
waveform. One SCR gate was dis-
connected to simulate an open or non-
functioning output SCR. Note that
each vertical division represents 50
volts and that each horizontal division
represents 2 milliseconds in time.
NOTE: Scope probes connected at
machine output terminals: (+) probe to
electrode, (–) probe to work.
SCOPE SETTINGS
Volts/Div....................50 V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger.........................Internal
0 V
2 ms
50 V
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
• Perform High Frequency Disable Procedure.
ABNORMAL OPEN CIRCUIT VOLTAGE - DC TIG MODE
ONE OUTPUT SCR NOT FUNCTIONING