INSTALLATION
A-2
A-2
SQUARE WAVE TIG 275
TECHNICAL SPECIFICATIONS - Square Wave TIG 275
For all Stick, DC TIG and Balanced AC TIG
Welding at 275A 40% Duty Cycle
w/o Optional K1620-1 Power Factor Capacitors
Based on the 1996 U.S. National Electrical Code
For Unbalanced AC TIG Welding above 180A,
255A 40% Duty Cycle, Maximum Penetration
w/o Optional K1620-1 Power Factor Capacitors
Based on the 1996 U.S. National Electrical Code
INPUT - SINGLE PHASE ONLY
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input
Voltage /
phase/
Frequency
208/1/60
230/1/60
460/1/60
575/1/60
Input
Amperes
111
100
50
40
Type 75°C
Copper
Ground Wire in
Conduit AWG
(IEC) Sizes
6 (13.3 mm2)
6 (13.3 mm2)
10 (5.3 mm2)
10 (5.3 mm2)
Fuse
(Super Lag)
or Breaker
Size
(1)
125
125
60
50
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
40°C (104°F) Ambient
4 (21.2 mm2)
4 (21.2 mm2)
8 (8.4 mm2)
10 (5.3 mm2)
Type 75°C
Copper
Ground Wire in
Conduit AWG
(IEC) Sizes
6 (13.3 mm2)
6 (13.3 mm2)
8 (8.4 mm2)
10 (5.3 mm2)
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
40°C (104°F) Ambient
3 (25.0 mm2)
3 (25.0 mm2)
8 (8.4 mm2)
8 (8.4 mm2)
Input
Amperes
130
120
61
49
Height
Width
Depth
Weight
Power
24.06 in.
19.15 in.
28.00 in.
Approx. 330 lbs.
Source
611 mm
486 mm
711 mm
150 kg.
Lift Hook add 3.57” (91 mm)
Power Source
33.40 in.
27.65 in.
40.65 in.
Approx. 375 lbs.
on
848 mm
702 mm
1033 mm
170 kg.
Undercarriage
PHYSICAL DIMENSIONS
Fuse
(Super Lag)
or Breaker
Size
(1)
150
150
70
60
(1)
Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of cur-
rent increases.
Code
Number
10523
10525
Input Current at
Input Current at
Input Current at
Idle Current
Idle Power
40% Duty Cycle
60% Duty Cycle
100% Duty Cycle
DC
AC
DC
AC
DC
AC
95/86/43 130/120/61
76/69/34
106/97/50
57/52/26
82/75/38
5/4/2
900 W Max.
43/35
61/49
34/28
50/41
26/21
38/31
2/1.5
900 W Max.
Standard
Voltage
208/230/460/1/60 (K1617-1)
460/575/1/60 (K1617-2)
RATED OUTPUT & ADDITIONAL OUTPUT CAPACITY
Duty Cycle
Amps
Volts at Rated Amperes
Current Range
Auxiliary Power
40% Duty Cycle DC TIG & AC/DC Stick
275 A
31.0 V
5-315 Amps
115 Volts AC, 10 Amps
NEMA Class II (40) AC TIG
255 A
16.1 V
Grounded NEMA-5-15R
Receptacle and
60% Duty Cycle DC TIG & AC/DC Stick
225 A
29.0 V
MAX O.C.V.
10 Amp Circuit Breaker
AC TIG
200 A
15.4 V
AC & DC 80V
100% Duty Cycle DC TIG & AC/DC Stick
175 A
27.0 V
Normal O.C.V.
AC TIG
150 A
14.8 V
72 V (AC) 59 V (DC)