B-4
OPERATION
B-4
10. WELD OUTPUT TERMINAL (TO ELECTRODE
HOLDER) WITH FLANGE NUT: Provides the con-
nection point for the electrode holder cable.
11. WELD OUTPUT TERMINAL (TO WORK) WITH
FLANGE NUT: Provides the connection point for the
work cable.
12. GROUND STUD: Provides a connection point for
connecting the machine case to earth ground for the
safest grounding procedure.
13. 50 AMP, 115/230 VOLT RECEPTACLE: Connection
point for supplying 230 volt power to operate one
electrical device.
14. 15 AMP, 115 VOLT DUPLEX RECEPTACLES:
Connection point for supplying 115 volt power to
operate one or two electrical devices.
15. CIRCUIT BREAKERS: Open the receptacle outlets if
a fault is detected in the circuit.
16. GLOW PLUG PUSH BUTTON: Activates
glow plug to preheat engine for cold weath-
er starting.
17. FUEL LEVEL GAUGE: Displays the level of diesel
fuel in the 9-gallon fuel tank. This gauge is not
located on the control panel. It can be found on
the fuel filler neck side of the machine between
the case side and the engine, mounted in the fuel
tank.
RANGER 8+ DIESEL
Содержание RANGER 8 + DIESEL
Страница 37: ...NOTES RANGER 8 ...