E-2
TROUBLE SHOOTING
ObserveallSafetyGuidelinesdetailedthroughoutthismanual
Ifforanyreasonyoudonotunderstandthetestproceduresorareunabletoperformthetests/repairssafely,contactyour
Local Lincoln Authorized Field Service Facility
fortechnicaltroubleshootingassistancebeforeyouproceed.
PROBLEMS
(SyMPTOMS)
RECOMMENDED
COURSE OF ACTION
POWER FEED™ 25M NNS
POSSIBLE
CAUSE
Fault Code
Err006
Err100
Err53Voltagesenseloss.
Err81Motoroverload,longterm.
Err82Motoroverload,shortterm.
Err263Nousableweldmodes.
Description
1.The wire feeder has not received
a recognition command from the
powersource.
1.The power source has issued a
shutdowncommand.
1.The wire drive motor has over-
heated.
1.Thewiredrivemotorcurrentdraw
has exceeded limits, usually
because the motor is in a locked
rotorstate.
1.The power source does not have
anyweldingprogramsloaded.
Possible Adjustments
1.Verifythepowersourceisoperat-
ing properly. (Status light steady
green.)
2.Check control cable for loose or
brokenleads.
3.See power source Instruction
Manual.
1.Verifythepowersourceisoperat-
ing properly (Status light steady
green.)
2.Check control cable for loose or
brokenleads.
3.See power source Instruction
Manual.
1.Check that the electrode slides
easilythroughthegunandcable.
2.Remove tight bends from the gun
andcable.
3.Check that the spindle brake is
nottootight.
4.Verify a high quality electrode is
beingused.
5.Waitfortheerrortoresetandthe
motor to cool. (approximately 1
minute).
1.Check that motor can turn freely
whenidlearmisopen.
2.Verify that the gears are free of
debrisanddirt.
1.See the power source Instruction
Manual for load welding pro-
grams.
Linc-Net System Error Codes
ArcLink System Error Codes
CAUTION