B-22
OPERATION
POWER FEED™ 25M NNS
Parameter
Definition
P.0
Exit Setup Menu
Thisoptionisusedtoexitthesetupmenu.WhenP.0isdisplayed,presstheLeftButtontoexit
thesetupmenu.
P.1
Wire Feed Speed Units
Thisoptionselectswhichunitstousefordisplayingwirefeedspeed.
English=inches/minutewirefeedspeedunits(default).
Metric=meters/minutewirefeedspeedunits.
P.2
Arc Display Mode
Thisoptionselectswhatvaluewillbeshownontheupperleftdisplaywhilewelding.
Amps=TheleftdisplayshowsAmperagewhilewelding(default).
WFS=TheleftdisplayshowsWireFeedSpeedwhilewelding.
P.3
Display Options
Thissetupparameterwaspreviouslynamed"DisplayEnergy"
If the previous software revision had this parameter set to display energy, that selection will
remain.
Thisoptionselectstheinformationdisplayedonthealphanumericdisplayswhilewelding.Notall
P.3selectionswillbeavailableonallmachines.Inorderforeachselectiontobeincludedinthe
list,thepowersourcemustsupportthatfeature.Asoftwareupdateofthepowersourcemaybe
neededtoincludethefeatures.
StandardDisplay=Thelowerdisplayswillcontinuetoshowpresetinformationduringandafter
aweld(default).
ShowEnergy=Energyisdisplayed,alongwithtimeinHH:MM:SSformat.
ShowWeldScore=Theaccumulativeweldscoreresultisshown
P.4
Recall Memory with Trigger
Thisoptionallowsamemorytoberecalledbyquicklypullingandreleasingtheguntrigger.To
recallamemory,quicklypullandreleasethetriggerthenumberoftimesthatcorrespondtothe
memorynumber.Forexample,torecallmemory3,quicklypullandreleasethetrigger3times.
To recall memory 1, quickly pull and release the trigger the number of user memories plus 1.
Memoriescannotberecalledwhilethesystemiswelding.
Disabled=Theguntriggercannotbeusedtorecallusermemories(default).
Enabled=Theguntriggercanbeusedtorecallusermemories.