P.22
Arc Start/Loss Error Time
Thisoptioncanbeusedtooptionallyshutoffoutputifanarcisnotestablished,orislostfora
specifiedamountoftime.Error269willbedisplayedifthemachinetimesout.Ifthevalueisset
to OFF, machine output will not be turned off if an arc is not established nor will output be
turnedoffifanarcislost.Thetriggercanbeusedtohotfeedthewire(default).Ifavalueis
set,themachineoutputwillshutoffifanarcisnotestablishedwithinthespecifiedamountof
timeafterthetriggerispulledorifthetriggerremainspulledafteranarcislost.Thisisdisabled
whileweldinginStick,TIGorGouge.Topreventnuisanceerrors,setArcStart/LossErrorTime
toanappropriatevalueafterconsideringallweldingparameters(run-inwirefeedspeed,weld
wire feed speed, electrical stick out, etc). To prevent subsequent changes to Arc Start/Loss
ErrorTime,thesetupmenushouldbelockedoutbysettingPreferenceLock=Yesusingthe
PowerWaveManagersoftware.
P.27
Language Select
SelectswhichlanguagewillbedisplayedontheUserInterface.
English(Default)
Italiano
Deutsch
Francais
Polski
Espanol
P.28
Display Workpoint as Amps Option
Thisoptiondetermineshowworkpointisdisplayed.
False=Theworkpointisdisplayedintheformatdefinedintheweldset(default).
True=Allworkpointvaluesaredisplayedasanamperage.
Note: This option may not be available on all machines. The power source must support this
functionality,orthisoptionwillnotappearinthemenu.
P.80
Sense From Studs
Usethisoptionfordiagnosticpurposesonly.Whenpoweriscycled,thisoptionisautomatically
resettoFalse.
False = Voltage sensing is automatically determined by the selected weld mode and other
machinesettings(default).
True=Voltagesensingisforcedto"studs".
P.81
Electrode Polarity
UsedinplaceofDIPswitchesforconfigurationoftheelectrodesenselead.Thisoptionallowsselec-
tionoftheelectrodevoltagesensepolarity.MostGMAWweldingproceduresuseElectrodePositive
welding.MostGTAWandsomeinnershieldproceduresuseElectrodeNegativewelding.
PositiveElectrodeWelding(default).
NegativeElectrodeWelding.
Thisoptionwillonlyappearinthemenuifthefeedheadboarddoesnothaveadipswitchtosetthe
polarity, and the power source does not support auto-hardware sense lead configuration. If this
optiondoesnotapperinthemenu,voltagesensepolaritycanbeselectedusingthedipswitches.