LMS6002D Quick Starter Manual for Evaluation Board
44 |
P a g e
© Copyright Lime Microsystems
Rev: 2.2
Last modified: 03/05/2012
The calibration data consists of frequency versus capacitance value responses which are defined
by minimum 2 point definition. The loaded VCO file should contain the above data. If not file
‘Dr2.vco’, provided with SW, should be loaded. To load a new VCO file press the ‘Load’ button
and follow the normal windows procedure to load a file. Then press OK. This new file will now
be downloaded on subsequent starts of the software.
4.5.5.
Tx LPF
The Tx LPF page contains the SPI controls for the transmitter low pass filters, notably the LPF
BW and also the controls for the DC calibration.
Figure 41 Tx LPF page
Description of each function available from this page is as follows:
DC Calibration
These are the individual controls for the DC correction and auto-calibration routines for the
TX LPF (controlled by the ‘Transmitter’ auto-calibration button on the ‘System’ page).
The Tx LPF DC calibration has 2 stages which can be calibrated:
TXLPF(I) at Cal module address 0
TXLPF(Q) at Cal module address 1
Power Control
Powers down the LPF modules, grayed out controls can be accessed by using direct signals
mode.