ES58 • EM58 MODBUS®
interface and the device as well. The meaning of each LED is explained in the
following table. In case of error, to know in detail which alarm has been
triggered, see the
ACTIVITY LED
Description
Blinking
GREEN
Indicates the device is sending or receiving a
message.
OFF
Indicates there is no send - receive activity.
STATUS/ERROR LED
Description
ON
GREEN
No active alarm.
Blinking
RED
Indicates there are either active alarms or an
internal error. For further information refer to
ON
RED
An hardware error has occurred which
prevents the unit from continuing to run.
Please turn the device off and then on again.
If the error is still on, please contact Lika
Electronic After Sales Service.
While performing the firmware upgrade operation (bootloading, refer to the “5.4
Update FW page - Firmware upgrade” section on page 45), the two LEDs operate
in a specific way, as explained in the following table.
ACTIVITY
LED
STATUS/ERROR
LED
Description
Blinking
GREEN
at 5 Hz
with duty cycle
= 50%
Blinking
GREEN
at 5 Hz
with duty cycle
= 50%
While downloading data to the flash memory
for upgrading the firmware of the unit (see
the “5.4 Update FW page - Firmware
upgrade” section on page 45), both LEDs blink
green at 5 Hz with duty cycle = 50%.
Blinking
RED
at 2 Hz with
duty cycle =
50%
Blinking
RED
at 2 Hz with
duty cycle =
50%
The operator has pressed the
BOOT STATE
button in the Firmware Upgrade page, the
encoder is waiting for the firmware upgrade
operation to start (by pressing the
DOWNLOAD
button). For any information
please refer to the “5.4 Update FW page -
Firmware upgrade” section on page 45.