5. Software Control - Lightware Device Controller
RAP-B511 series
– User's Manual
39
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
Schema ID
Device Type
Generic LWR-D
MMX6X2-HT200
MMX6X2-HT210
MMX6X2-HT220
Generic LWR-E
MX-FR (IB/OB-A)
UMX-OPT-TX150R
UMX-TP-TX100
Generic LWR-F
UBEX-PRO20-HDMI-F110, -F120
Generic LWR-G
VINX-120AP-HDMI-ENC
VINX-120AP-HDMI-ENC-DNT
VINX-210AP-HDMI-ENC
VINX-110AP-HDMI-DEC
5.5.
Control Menu
5.5.1.
RS-232
RS-232 Tab in Control Menu
The following settings and functions are available (both on local and TPS serial ports):
▪
Operation mode: Control, Command Injection, or Disconnected (for more details about serial interface
modes see the
section);
▪
Baud rate: 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200;
▪
Data bits: 8 or 9;
▪
Parity: None, Odd, or Even;
▪
Stop bits: 1, 1.5, or 2;
▪
Command injection: enable or disable; port number;
#commandinjection
▪
Control protocol: LW2 or LW3;
#protocol
#rs232 #rs-232 #serial
▪
Message sending via serial port;
#message
▪
Reloading factory defaults (see factory default settings in the
section).