10. Appendix
RAP-B511 series
– User's Manual
116
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
10.3.
Cable Wiring Guide
RS-232 Data Transmission
Room Automation Panel is built with 3-pole Phoenix connector. See the below examples of connecting to a
DCE (Data Circuit-terminating Equipment) or a DTE (Data Terminal Equipment) type device:
Lightware device and a DCE
D-SUB 9 - Phoenix
Lightware device and a DTE
D-SUB 9 - Phoenix
TX RX
1
6
9
5
2: TX data transmit
3: RX data receive
5: Ground
TX RX
1
6
9
5
2: TX data receive
3: RX data transmit
5: Ground
INFO:
The RAP-B511 series works as a DCE unit according to its pin-out.
10.4.
Button Numbering
1 2 3
6 7 8
9 10 11
4 5
10.5.
Mechanical Drawings
Dimensions are in mm.
RAP-B511-EU -K, -W, -S
INFO:
All the RAP-B511-EU models have the same size.
152
82
50
8.3
9.3
95
39.3
2 gang EU
30
30
71
35.5
35.5
79
71
131
140.8
40.5