7. LW3 Programmers’ Reference
UMX-TPS-TX100 series – User's Manual
135
Applied firmware packages: (UMX-TPS): v1.5.0b4 | (WP-UMX-TPS): v1.4.0b8 | (FP-UMX-TPS): v1.4.0b8 | LDC software: v2.5.6b2
7.19.9.
Set the Active Timeout
This property is responsible for clearing the
ActiveRx
,
ActiveRxHex
,
ActiveHash
properties after the elapsed
time. Default value is 50ms.
Command and Response
ç
SET·/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=
<a_timeout>
æ
pw·/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=
<a_timeout>
Parameters
The
<a_timeout>
parameter is the active timeout value (ms) between 0 and 255.
Example
ç
SET /MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=255
æ
pw /MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=255
7.19.10.
Running an Immediate Event Action
DIFFERENCE:
This command is available from firmware v1.6.0.
When a message is recognized (DelimiterHex is detected in the message, or TimeOut has been elapsed
since receiving the last data bit) a specific Action of an Event can be run by the following command.
Command and Response
ç
SET·/CTRL/TCP/C
<loc>
.ActionTrigger=
<event_nr>
æ
pw·/CTRL/TCP/C
<loc>
.ActionTrigger=
<event_nr>
Parameters
The
<event_nr>
means the number (location) of the linked Event Action without letter 'E'. (There is no need
to define a Condition in the linked Event.)
Example
ç
SET /CTRL/TCP/C1.ActivePropertyTimeout=255
æ
pw /CTRL/TCP/C1.ActivePropertyTimeout=255