7. LW3 Programmers’ Reference
UMX-TPS-TX100 series – User's Manual
110
Applied firmware packages: (UMX-TPS): v1.5.0b4 | (WP-UMX-TPS): v1.4.0b8 | (FP-UMX-TPS): v1.4.0b8 | LDC software: v2.5.6b2
7.6.23.
HDCP Setting (Output Port)
HDCP capability can be set to Auto/Always on the output ports, thus, non-encrypted content can be
transmitted to a non-HDCP compliant display. See more information in the
Command and Response
#hdcp
ç
SET·/MEDIA/VIDEO/
<out>
.HdcpModeSetting=
<HDCP_mode>
æ
pw·/MEDIA/VIDEO/
<out>
.HdcpModeSetting=
<HDCP_mode>
Parameters
Identifier
Parameter description
Value
Parameter value
<HDCP_mode>
HDCP mode
0
Auto
1
Always
Example
ç
SET /MEDIA/VIDEO/O1.HdcpModeSetting=0
æ
pw /MEDIA/VIDEO/O1.HdcpModeSetting=0
7.6.24.
HDMI Mode Settings (Output Port)
Command and Response
ç
SET·/MEDIA/VIDEO/
<out>
.HdmiModeSetting=
<mode>
æ
pw·/MEDIA/VIDEO/
<out>
.HdmiModeSetting=
<mode>
Parameters
Identifier
Parameter description
Value
Parameter value
<mode>
HDMI mode
0
Auto
1
DVI
2
HDMI 24 bit
3
HDMI 30 bit
4
HDMI 36 bit
Example
ç
SET /MEDIA/VIDEO/O1.HdmiModeSetting=2
æ
pw /MEDIA/VIDEO/O1.HdmiModeSetting=2
7.6.25.
Color Space Setting (Output Port)
Command and Response
#colorspace
ç
SET·/MEDIA/VIDEO/
<out>
.ColorSpaceSetting=
<colorspace>
æ
pw·/MEDIA/VIDEO/
<out>
.ColorSpaceSetting=
<colorspace>
Parameters
Identifier
Parameter description
Value
Parameter value
<colorspace>
Color space conversion
0
Auto
1
RGB
2
YCbCr 4:4:4
3
YCbCr 4:2:2
Example
ç
SET /MEDIA/VIDEO/O1.ColorSpaceSetting=2
æ
pw /MEDIA/VIDEO/O1.ColorSpaceSetting=2
7.6.26.
TPS Mode Settings
Command and Response
#tpsmode
ç
SET·/REMOTE/
<port>
.tpsModeSetting=
<tps_mode>
æ
pw·/REMOTE/
<port>
.tpsModeSetting=
<tps_mode>
Parameters
Identifier
Parameter description
Value
Parameter value
<mode>
TPS mode
A
Auto
H
HDBaseT
L
Long reach
1
LPPF1
2
LPPF2
INFO:
See more information about TPS modes in the
section.
Example
ç
SET /REMOTE/S1.tpsModeSetting=A
æ
pw /REMOTE/S1.tpsModeSetting=A
INFO:
to query the parameter.