1. System Overview
Created to work with Lytespan Radius
®
, Basic
®
, and
Advent
®
Track and all Lytespan Track Heads, ATOM is
easily installed and requires no special wiring. A simple
hand-held
Laser Remote Control (LRC)
allows the user to
first activate the system with a laser, and then program
individual or multiple Track heads using infrared signals.
Easily retrofitted to existing installations, ATOM offers
even more flexibility and control than multi-circuit track.
ATOM provides up to six programmable scenes plus
On/Off scenes, programmable time delays, fading
effects, and cycle effects by grouping fixtures on the
same sequence. When integrated with
Lightolier
Controls Compose PLC Firewall (CPLCFW4 & CPLCFW8)
,
ATOM can communicate across multiple circuits of
Track to provide the ultimate in lighting control.
Ideal for dimming incandescent and low-voltage
fixtures with the
Addressable Track Dimming Module
(DM)
, ATOM also controls non-dimming compact
fluorescent and metal halide sources with the
Addressable Track Non-Dimming On/Off Module (NDM)
.
Additional components of the system consist of:
Addressable Track Master Module (TM)
- permits scene
control via line carrier signal among Addressable Track
Dimming and Addressable Track On/Off Modules.
Wall Remote Control (WRC)
- A hard wire unit will
interface with ATOM TM & Lightolier Controls Compose
System.
In-Line Filter (CPLCILF20)
– Recommended for each
track circuit with an ATOM installation. Reduces
unwanted electrical noise on track circuit.
ATOM is compatible with Lightolier Controls Compose
System.
2. Understanding the Components
Addressable Track Dimming Module (DM) – CAM250VA
Individually addressable module that mounts anywhere
along the track and accepts any Lytespan Line & Low
Voltage Incandescent luminaire (see luminaire compati-
bility for exceptions) for the purpose of addressing a
selected single luminaire for raising and lowering the
light level (dimming) or switching On/Off, while powered
by the same track. Programmable to store desired light
levels of single luminaires or to group with two or more
luminaires within the same system for the purpose of
creating light scenes and effects
(including kinetic lighting effects)
Luminaire Compatibility:
Module can be used with any Lytespan Line & Low
Voltage Incandescent luminaire, 250W Max. DO NOT
USE with Power Jack, Metal Halide, Fluorescent, or
Convenience Outlet Units
See individual luminaires instruction sheet for
installation into Module.
Table of Contents
1.
System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.
Understanding the Components . . . . . . . . . . . . . . . 3
Addressable Track Dimming Module
(DM) – CAM250VA . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Addressable Track Non-Dimming
On/Off Module (NDM) – CAM250ND . . . . . . . . . . . 4
Addressable Track Master
Module (TM) - CAMTM . . . . . . . . . . . . . . . . . . . . . . 5
Laser Remote Control (LRC) - CAMLRC . . . . . . . . . 5
Wall Remote Control (WRC) - CAMWRC . . . . . . . . 6
3.
Installation of Modules to Lytespan
Track Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.
ATOM Laser Remote Control (LRC) . . . . . . . . . . . . 8
Feature Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Replacing Batteries . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.
First Time Installation & Test . . . . . . . . . . . . . . . . . . 11
Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.
Programming ATOM (Basic) . . . . . . . . . . . . . . . . . . 12
Programming Modules . . . . . . . . . . . . . . . . . . . . . . 13
Programming A System . . . . . . . . . . . . . . . . . . . . . . 14
7.
Programming ATOM (Advanced Features) . . . . . . 17
8.
Operation of the ATOM System . . . . . . . . . . . . . . . 20
Operating Commands . . . . . . . . . . . . . . . . . . . . . . . 20
Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9.
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
10.
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27