Grounding and Power Requirements
LifeSpan equipment must be grounded. Improper connection of the equipment’s grounding conductor
can result in the risk of electric shock. Check with a qualified electrician or service person if you are
in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the
product or use a ground plug adaptor to adapt to a non-grounded outlet. If the plug will not fit in the
outlet, have the proper outlet installed by a qualified electrician.
An extension cord should not be used between the equipment and the wall outlet.
The unit should not be plugged into a GFI plug or on a GFI circuit. The unit may not work as it may trip
the GFI circuit.
This product should only be run on the proper power designed for this unit. To locate the proper power
outlet for your area please refer to FIG. 2 (example for the U.S. and Canada, these units require a 115 V
NEMA 5 - 15 non GFI circuit.)