33
TROULESHOOTING |
E08
Hardware error
Check whether the power wire is dropped
Check the control board, replace if damaged.
E16
Incline failure
Re-connect or replace the wire for the incline
motor. Replace the incline motor witha new one.
E17
Calibration failure
Check if the incline wire is connected properly.
Recalibrate after connecting the ascending wire.
E21
Data Saving Exception
Power off the power for two minutes and power
it off again. If you cannot start the machine,
replace the control board
E31
Over Temperature
Run the machine after the temperature is
normal.
E32
Motor Reverses
Check whether the motor cable UVW is properly
connected.
E33
Motor parameter error
Provide correct motor parameters.
E22
Communication timeout
Check whether the wires between the console
and the control board is loose or dropped Check
whether the control board is damaged. Check
whether the console is damaged. Power off for 2
minutes, and restart the machine.
E50
Other errors
Replace the control board.