- 20 -
- 17 -
ICE-HARVEST:
During the ice-harvest process, the reversing valve is opened, the ice tray will be heated,
and the connection between the ice cube and the ice tray will be melted. When the ice
cube cannot be attached to the ice tray due to its own weight, it will fall down and one
ice-harvest is finished.
When each batch of ice fall off to the ice bin, please use an ice spoon to shovel them into
32 small ice cubes to hold more ice.
When the ice falls, the flap is flipped, and then the flap is reset due to its own weight, then
the machine starts to make the next ice. However, due to too many ice cubes are in the
ice bin, and they press against the flaps to make the flaps cannot be reset, the control
chip will judge that the ice is full and temporarily stop and will restart until the flaps are
reset.
WARNING: CLEAN WATER ONLY
Ice bin drain hose
Water inlet hose
进水管
排水管
OPERATING INSTRUCTIONS
ICE-MAKING:
1. After all the water pipes are connected, plug on the main power supply plug.
2. Press On/off button to start the motor, then press button to choose the size of
ice, and ice maker will determine the ice making time according to the ambient
temperature. Then the compressor will start and enter the automatic ice-making process.
3. After 3 minutes, the circulating water pump start to work, ice making begins. During the
ice making process, the water pump will last running, and the water will flow down from
the top of the ice tray into the water tank, then the water will slowly cool until it freezes.
4. When the ice cube reaches the reservation time position, the program will switch to
the ice-harvest process.
Operating Video:
www.amazon.com/vdp/09a318b666da4aff8488677d84186f21?ref=dp_vse_ibvc0
Water Inlet Supply
Bucket Water Supply
Tap Water Supply
Valve Direction
Please adjust the valve direction
correspondingly BEFORE use
How to Remove the Water Inlet Pipe
?
1. Remove the Blue Buckle
2. Press the white part as the picture
and pull out the Inlet Pipe
Each outlet has been marked on
the unit. If there is a conflict with
the instruction, it may be that the
workers pasted it incorrectly.
Please take the instruction as the
standard.
TROUBLESHOOTING
DIGITAL WINDOW FAULT CODE
Fault indication: ice full light flashes quickly: ambient temperature (sensor) fault, shutdown
.
The ice full indicator and the water shortage indicator flash alternately: the open and
closed signals of the ice full switch cannot be detected for 3 consecutive times, the
machine stops working and reports a mechanical failure.