Anchor Types
Anchor
Subfloor between unit and concrete
0” to 1/2” (12.7mm) thick
Subfloor between unit and concrete
over 1/2” (12.7mm) thick
Static
Imperial
KH-EZ 1/4” x 4”
KH-EZ 1/4” x 5”
Metric
HUS-H 6mm x 120mm
HUS-H 6mm x 150mm
Anchor Specifications
Static Anchor
Minimum Concrete
Thickness
Minimum Drill Depth
in Concrete
Minimum Concrete
Embedment
Minimum concrete
compressive strength
KH-EZ 1/4”
4-1/8” (105mm)
1/2” (12.7mm)
beyond anchor
length
2-1/2” (63.5mm)
3000psi (20 N/mm2)
HUS-H 6mm
3-3/32" (100mm)
25/64" (10mm)
beyond anchor
length
2-1/64” (55mm)
3000psi (20 N/mm2)
Pullout Force
Life Fitness
specifies Hilti
™
static and dynamic anchors. According to the anchor manufacturer, the recommended
design pullout force (in tension) for the specified anchors, when properly installed in cracked concrete, is provided in
the side table. This table should be used for reference only; for additional and up-to-date information on the anchor
capabilities or the design pullout force in other substrates, please consult Hilti directly at
Selected Anchor
Design Resistance in Tension *
KH-EZ 1/4" x 4”
830 lb
HUS-H 6MM x 120MM
3.3 kN
KH-EZ 3/8” x 4”
1535 lb
KH-EZ 3/8” x 5”
1535 lb
HUS-H 8MM x 120MM
3.3 kN
HUS-H 8MM x 150MM
3.3 kN
HSL-3 and HSL4 M 8/40
2000 lb
HST M12 x 115/20
8 kN
HST M12 x 195/200
8 kN
KB-TZ 3/8” x 3-3/4”
1615 lb
* Design strength extracted from the Hilti Anchor Fastening Technology Manual issued September 2014.
Tools Required
WARNING: Adhere to manufacturer’s equipment warnings and guidelines. Follow manufacturer’s instructions
for proper usage.
Static Anchor
• Floor scanner / rebar detector (optional)
• 1” L-shape SDS rotary hammer
• 1/4" x 12" (6mm x 305mm) carbide drill bit (for 1/4”
(6mm) anchors)
• 3/8" x 12" (8mm x 305mm) carbide drill bit (for 3/8”
(8mm) anchors)
• Safety glasses
• Extension cord
• Impact wrench
• Vacuum (for debris)