Elevation 95X-ALLXX-01 Commercial Cross-trainer
“How To…”
64
Generator
Mounting
Bracket
mark the
position of
the bracket
here
Generator
Mounting
Nuts (4)
Tension Bolt
tightening the tension
bolt in the right-hand
hole causes the
generator mounting
bracket to slide up
HOW TO... REPLACE THE POLY-V BELT
Tools required: Phillips screwdriver, 9/64 Allen wrench, 19mm open end wrench, 13mm and 19mm socket wrenches,
felt-tip marker
Estimated time required: 60 minutes
1.
If the cross-trainer has line cords, unplug them
from the wall outlets.
2.
Remove the right rear pedal lever clevis covers.
(See the “How To…” on page 47.)
3.
Remove and save the bolt and washer that
secure the pedal lever to the crankarm shaft.
4.
Slide the pedal lever assembly off the crankarm
shaft.
5.
Remove both rocking link assemblies. (See the
“How To…” on page 48.)
6.
Remove the right upper rocker assembly cover.
(See the “How To…” on page 51.)
7.
Remove the rear tower rear cover. (See the
“How To…” on page 50.)
8.
Remove the top rear tower cover. (See the “How
To…” on page 49.)
9.
Mark the position of the generator-mounting
bracket on the metal plate behind it.
10.
Loosen the four generator mounting bolts.
11.
Remove the tension bolt completely from the
hole in the left side of the mounting bracket.
12.
Insert the tensioning bolt into the hole in the
right side of the bracket and turn it clockwise.
This will tighten the bolt and raise the mounting
bracket, allowing the Poly-V belt to be easily
removed from the generator pulley.
13.
Remove the Poly-V belt from the generator
pulley.
14.
Remove the Poly-V belt from the generator
pulley.