L I F A N P O W E R U S A
Page 39
Troubleshooting
IF THE ENGINE WILL NOT START:
1.
Check to ensure switches are in the “ON” position. (Both unit and engine)
2.
Check engine oil level. Your unit possesses a Low Oil Alarm System that will not allow your
engine to start if the oil is below safe operating levels. This feature is installed to increase the
life of your engine and prevent engine damage. If oil level is low, fill to the full mark on
dipstick. Refer to the Product Specifications for exact oil type and amounts.
3.
Check the fuel level to insure adequate fuel. Add fuel if necessary.
4.
Remove and inspect the spark plug for cleanliness and proper electrode gap. If needed, clean
or replace the spark plug. Refer to Spark Plug Maintenance in the Maintenance section of the
Owner’s Manual for proper procedure.
NOTE:
Periodically on the initial start--up or after the unit has been stored for a long
period of time, the float for the “Low Oil Alarm System” will stick to the bottom of your
oil pan. Locate the two (2) wires to the Low Oil Sensor Diode (refer to figure on the right)
located on the side of the engine block. Unplug these wires and,
only after ensuring the
engine is full of oil,
start the engine and allow to run until warm (normally 20 minutes, as
this will heat the oil and release the float on the Low Oil Alert System). Then re- plug the
wires to the terminals on the Low Oil Alarm Sending Unit.
UNIT DOES NOT PROVIDE ELECTRICAL CURRENT:
1.
Plug in a small appliance or tool to test.
2.
Check if the AC (or DC) Circuit Breaker is in the “ON” position. If not, place in “ON” position.
If equipped with a GFCI receptacle, re--set GFCI Breaker by pushing in the reset button in the
middle of the GFCI’s faceplate (this must be done with the engine running).
3.
If your unit still does NOT produce electricity after performing the previous checks, call
LIFAN Power USA at 1--866--471--7464, your dealer, or authorized Service Center.
Содержание ENERGY STORM ESI2500iER-EFI-CA
Страница 1: ......
Страница 2: ...L I F A N P O W E R U S A Page 1 THANK YOU FOR YOUR PURCHASE PLEASE READ ...
Страница 55: ...L I F A N P O W E R U S A Page 54 APPENDIX ...
Страница 56: ...L I F A N P O W E R U S A Page 55 Wiring Diagram ESI2500iER EFI CA FME to Insert Wiring Diagram ...
Страница 57: ...L I F A N P O W E R U S A Page 56 ESI2500iER EFI CA Exploded View Parts FME to Insert Exploded View Diagram ...
Страница 58: ...L I F A N P O W E R U S A Page 57 Wiring Diagram ESI3100iER EFI CA FME to Insert Wiring Diagram ...
Страница 59: ...L I F A N P O W E R U S A Page 58 ESI3100iER EFI CA Exploded View Parts FME to Insert Exploded View Diagram ...
Страница 69: ...L I F A N P O W E R U S A Page 68 ...
Страница 75: ...L I F A N P O W E R U S A Page 74 ...
Страница 107: ...L I F A N P O W E R U S A Page 106 ...