Page 25
Operation of Generator
HOW TO USE YOUR GENERATOR
GENERATOR LOCATION:
•
To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a
length of heavy cable between the generator's grounding terminal and an external ground source.
•
This generator is not intended, nor designed, for use as a standby power supply, or to be connected to an automatic
transfer switch (ATS); it should never be used as such. Severe property damage and/or severe personal injury or
death may result. Such back feed may electrocute utility company workers or others who contact the lines during a
power outage. When utility power is restored the generator may explode, burn, or cause fires in the building’s
electrical system.
•
Do not attempt to connect generators in parallel unless it is a ESI2500 or ESI3100 inverter generator, which are
designed and equipped for parallel connection.
•
Indoor use of a generator can kill quickly. Generators should be used outdoors only.
•
The total wattage of all appliances connected must be considered.
•
Do not exceed the current limit specified for any one receptacle.
•
Do not connect the generator to a household circuit. This could cause damage to the generator or to
electrical appliances in the house.
•
Do not modify or use the generator for purposes other than its intended use.
•
Do not connect an extension to the exhaust pipe.
•
When an extension cord is required, be sure to use a rubber sheathed flexible cord. Also be sure to use the proper
size and length cord.
–
16 Gauge Cords - a 16 gauge cord between 0 and 100 feet long will safely handle tool and appliance loads up to 10
amps.
–
14 Gauge Cords - a 14 gauge cord between 0 and 50 feet long will safely handle tool and appliance loads between 10
and 15 amps.
–
12 Gauge Cords - a 12 gauge cord between 50 and 100 feet will safely handle tool and appliance loads between 10 and 15
amps.
Содержание ENERGY STORM ESI2500iER-EFI-CA
Страница 1: ......
Страница 2: ...L I F A N P O W E R U S A Page 1 THANK YOU FOR YOUR PURCHASE PLEASE READ ...
Страница 55: ...L I F A N P O W E R U S A Page 54 APPENDIX ...
Страница 56: ...L I F A N P O W E R U S A Page 55 Wiring Diagram ESI2500iER EFI CA FME to Insert Wiring Diagram ...
Страница 57: ...L I F A N P O W E R U S A Page 56 ESI2500iER EFI CA Exploded View Parts FME to Insert Exploded View Diagram ...
Страница 58: ...L I F A N P O W E R U S A Page 57 Wiring Diagram ESI3100iER EFI CA FME to Insert Wiring Diagram ...
Страница 59: ...L I F A N P O W E R U S A Page 58 ESI3100iER EFI CA Exploded View Parts FME to Insert Exploded View Diagram ...
Страница 69: ...L I F A N P O W E R U S A Page 68 ...
Страница 75: ...L I F A N P O W E R U S A Page 74 ...
Страница 107: ...L I F A N P O W E R U S A Page 106 ...