Malfunctions
- No display after power up.
The device houses a slow-blow fuse for feeble currents of 6.30 A protecting the equipment
of wrong polarities on the supply line. When the fuse is blown, cable and polarity have
absolutely be checked (pin1 = 0 V, pin 4 = +24V).
- No error message but motoryoke does not move
–
Check DMX-addressing (
P01, DMX-Address motoryoke, page 26
).
–
Is the speed-channel not set to 0? Check it with the DMX-tester in P30, page 37
- No error message but the Focus module does not move
–
Is the focus-module switched on? Check
P02, Focus module ON/OFF, page 27.
–
Is the focus-cable well connected?
–
Check the incoming DMX-values with the DMX-tester in
P30, page 37.
The focus-
channel is start-channel (
P01, page 26
) + 4 or 5 (depends on
P27, page 36
). Refer to
DMX-channels motoryoke, page 25.