P14 Focus/rotation unit 0%-value adjustment
At this point the
position of the focus or the rotation unit for 0% DMX-value
can be set.
This function is only available, when focus module is switched on. This can be done in
menu
P02, Focus module ON/OFF, page 27.
Caution!
The 0%-value must be
smaller
than the the 100%-value! (P14 smaller than P15)
You have the possibility to set this value automatically. When depressing the menu button
again (see operation), the Focus unit moves to the mechanical stop and stops moving.
Now the focus unit should be moved 20 values by depressing the UP-key. This is to avoid
a crash during normal moving.
Caution!
Do
not
use the auto-adjustment function with the rotation!
Range of values:
10..4000 units (value of the absolute value device)
Operation:
depress You are now on menu level. The last adjusted menu
point is displayed, e.g.:
Menu P01: DMX address motoryoke
depress ... until
Menu P14
is displayed
.
depress The second line displays the currently adjusted value.
depress Adjust the desired value
or
depress for automatic movement to the mechanical stop.
Corrections with UP/DOWN keys are still possible.
depress You are back on menu level.
depress The equipment is ready for operation.