DL-SC41UP-BXTX Installation Guide
25
RS232 and TCP/IP Control
RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None
Telnet Settings: User defined IP address (default IP address:192.168.0.178), port 4001
The commands are case sensitive and must be terminated with a carriage return <CR> and line feed <LF>
Description
Command
Examples
Set output switching mode to manual
switching or to auto switching
NOTE:
When using the manual
switching commands in this API the
switching mode status should be set
to MANUAL
#SET_AUTO_SWITCH {O} {m}
{O}
= HDMI, HDBT
{M}
= 0 (MANUAL)
1 (AUTO)
Command:
#SET_AUTO_SWITCH HDMI 1
Response:
@HDMI_AUTO_SWITCH 1
Query switching mode status
#GET_AUTO_SWITCH
Command:
#GET_AUTO_SWITCH
Response:
@HDMI_AUTO_SWITCH 1
Routing inputs to outputs
#SET_AV {O} {I}
{O}
= HDMI, HDBT
{I}
= H1 (HDMI 1)
H2 (HDMI 2)
DP (DISPLAYPORT)
C (USB-C)
RXH (RX HDMI)
NOTE:
When using RXH
parameter this can only be used
when the optional DL-SCU-RX is
used with the DL-SC41U-TX
Command:
#SET_AV HDMI H1
Response:
@HDMI_AV H1
Query routing status
#GET_AV
Command:
#GET_AV
Response:
@HDBT_AV H1
@HDMI_AV H2