Troubleshooting
8-6
InterReach Fusion SS Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620605-0-20 Rev A
{MF20}Hardware failure (DL Pilot PLL Unlock)
Cycle power once. If the fault persists, replace the Hub.
{MF21}Hardware failure (UL PLL Unlock)
Cycle power once. If the fault persists, replace the Hub.
{MF22}Hardware failure (UL PLL Unlock)
Cycle power once. If the fault persists, replace the Hub.
{MF23}Hardware failure (UL PLL Unlock)
Cycle power once. If the fault persists, replace the Hub.
{MF24}Frequency band not programmed
Use AdminBrowser to program the frequency band.
{MF25}Hardware failure (DL Pilot AGC)
Cycle power once. If the fault persists, replace the Hub.
{MF26}Hardware failure (DL Pilot AGC)
Cycle power once. If the fault persists, replace the Hub.
{MF30}Hardware failure (UL Path)
Re-run system test. If the fault persists, swap positions of the last two
RAUs, and re-run the system test. If the fault persists, replace the
Hub.
{MF41}Hardware failure (No communications with
auxiliary board)
Replace the Hub.
{EF01}Software error occurred and recovered
If this happens repeatedly, replace the Hub. (Log entry only.)
{EF02}Software error occurred and recovered
If this happens repeatedly, replace the Hub. (Log entry only.)
{EF03}Software error occurred and recovered
If this happens repeatedly, replace the Hub. (Log entry only.)
{EF04}Software reset occurred and recovered
If this happens repeatedly, replace the Hub. (Log entry only.)
{EF05}Software error occurred and recovered
If this happens repeatedly, replace the Hub. (Log entry only.)
{EF06}Hardware failure (SPI)
Cycle power once. If the fault persists, replace the Hub.
{EF07}Temperature is too high
Replace the Hub if fan failure. Check the fan for rotation, air flow
blockage, and dust. Check the room environmental controls.
{EF08}Frequency band not programmed
Use AdminBrowser to program the frequency band.
{EF16}Hardware failure (No communications with the
main board)
Replace the Hub.
{EF17}RAU 1 disconnected
Check the CATV cable for shorts/opens, especially on new installa-
tions. Try another hub port. If no fault is reported, flag the previous
port as unusable and replace the hub when possible. Otherwise,
replace the RAU. Use “Clear All Disconnect Status” command to
clear fault, or physically connect the RAU.
{EF18}RAU 2 disconnected
Check the CATV cable for shorts/opens, especially on new installa-
tions. Try another hub port. If no fault is reported, flag the previous
port as unusable and replace the hub when possible. Otherwise,
replace the RAU. Use “Clear All Disconnect Status” command to
clear fault, or physically connect the RAU.
{EF19}RAU 3 disconnected
Check the CATV cable for shorts/opens, especially on new installa-
tions. Try another hub port. If no fault is reported, flag the previous
port as unusable and replace the hub when possible. Otherwise,
replace the RAU. Use “Clear All Disconnect Status” command to
clear fault, or physically connect the RAU.
Table 8-1
Faults Reported by the Fusion SingleStar Hub
Fault Message
Action