- 41 -
Copyright © 2019 - 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.
Part 2 Functions & Controls
5.4 Auto restart Operation
• Whenever there is electricity failure to the unit, and after resumption of the power, unit will start in the same mode prior
to the power failure. Memorized condition are on / off condition, operating mode (cooling/ heating), set temperature
and fan speed. The unit will memorize the above conditions and start with same memorized condition.
5.2 Auto cleaning operation
• Function used to perform Self Cleaning to prevent the Unit from Fungus and bad odor.
• Used after the Cooling Operation before turning the unit off, clean the Evaporator and keep it dry for the next opera-
tion.
• The function is easy to operate as it is accessed through the Remote controller.
Unit
Operation
ON
OFF
Comp.
Indoor
Fan
ON
OFF
ON
OFF
Setting step
OFF
L Low
Setting step
(Cooling Only)
5.3 Auto changeover operation
• The air conditioner changes the operation mode automatically to keep indoor temperature.
• When room temperature vary over ±2 °C with respect to setting temperature, air conditioner keeps the room tempera-
ture in ±2 °C with respect to setting temperature by auto change mode.
SET Temp.
+0.5 ˚C
-0.5 ˚C
-2 ˚C
+4 ˚C
+2 ˚C
Cooling
operation
Heating operation
Cooling
operation
Cooling thermo off
Heating thermo off
Switching point
Switching point