- 66 -
Copyright © 2018 LG Electronics Inc. All rights reserved.
Only training and service purposes.
1.4 Remote Controller
To solve various troubles while using control panel, please read following FAQ (Frequently Asked Questions).
For your convenience, all questions are classified according to topics.
No Topic Question Answer
1
2
3
Power button does
not bright
Some texts are
displayed
automatically
Water tank heating
or related features
are not permitted
System installation is
finished. Also, all wirings
including power connection
is all right. But when the
power button in front of the
control panel is pushed, it
does not bright.
Although nobody touched
control panel, someties it
displays specific texts and
the system operates
automatically.
Setting water tank
temperature is not
permitted although the
water tank is installed.
• There can be a problem in wiring between PCB
and control panel. Open control box and find
‘CN_REMO’ connector at the PCB. If the connector
is empty or nothing is connected, please connect it
with end of wire which is from control panel then
restart the system.
• Check if external controller is connected like
thermostat. If thermostat is connected to the
system and it is configured exactly, you can see
‘Thermostat’ text at the display of the control panel.
It is normal condition that power button of control
panel does not work when thermostat is installed.
• It is normal condition. Basically, two features can be
operated without user’s decision – one is system
protective operation, the other is ‘background water
tank heating operation’, which is heating inside the
water tank while space heating is not used or the
system is not working. System protective operation
is, as letter says, for the purpose of securing the
system from worse condition. Anti-freezing
operation, for example, is one of the protective
operation. It is essential to start protective operation
to prevent potential malfunction and to keep
possible accidents. On the other hand, background
water tank heating operation is not protective
operation but to supply warm water to end-user.
The background water tank heating operation is
only started when the water tank temperature is
under the specific temperature.
Following two conditions should be satisfied.
• Check if ‘Water tank enable/disable’ is correctly
displayed or not. To use water tank, end-user must
push On/Off button focused on hot.
• Also, check if DIP switch setting is correct or not.
To identify the DIP switch setting, open the control
box inside the unit. Unless 2nd and 3rd pin of DIP
switch setting is 01(OFF-ON) or 10(ON-OFF), the
water tank heating will not be configured.