background image

40

ENGLISH

Shut Down the System

This command allows you to shut down the system in an orderly manner. Use this command to shut down 

the PCS500R, for example, if you intend to physically move the unit from one location to another. It is also 

recommended that you run this command from the PCS500R Service Port in order to track detailed shutdown 

log messages.

Note

: Once you use this command, you must remove power from (i.e., unplug) the unit and then plug the AC 

power cord back into a powered AC line receptacle when you are ready to restart the server. It is not possible to 

restart the server remotely.
1  Log in to the PCS500R as described on page 25
.
2  At the 

   prompt, type shut and press 

.

The system will prompt for confirmation:

3  Either:

• 

Type   and press 

 to shut down the system immediately. The shutdown typically takes about a minute. 

When the PCS500R is in its shutdown state, the front panel LED will blink steadily green.

• 

Type   and press 

 to return to the Main Menu without shutting down the system.

Reset the System

1  If not already logged in, log in to the PCS500R as described on page 25.
2  At the 

   prompt, type reset and press 

.

The system will prompt for confirmation:

3  Either:

• 

Type   and press 

 to initiate an immediate reset of the PCS500R. The reset process may take several 

minutes, after which the system resumes normal operation.

• 

Type   and press 

 to return to the Main Menu without resetting the system.

Содержание PCS500R Pro:Centric

Страница 1: ...Installation Setup Guide Warranty PCS500R Pro Centric Server www lg com Copyright 2021 LG Electronics Inc All Rights Reserved SAC35974191 2105 REV00 ...

Страница 2: ...with RF Output 18 Typical Setup Diagram for PCS500R with IP Output 19 VPN Network Connections Overview 20 Setting Up the Pro Centric Network 24 PCS500R Configuration Options 24 Network and Communication Setup 25 Log In to the PCS500R and Access the Main Menu 26 View System Information 27 Modify Network Settings 31 Modify the Server Host Name via TUI 32 Modify the Server Host Name via CLI 33 Set th...

Страница 3: ...3 ENGLISH 42 Troubleshooting 42 PCS500R Setup 43 PCS500R Communication 44 Specifications 46 Open Source Software Notice Information 68 LG PCS500R Pro Centric Server Warranty ...

Страница 4: ...NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER TO QUALIFIED SERVICE PERSONNEL This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is intended to alert the user to the presence of important operating and maintenance ...

Страница 5: ...hen the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Use authorized detergent only when cleaning the product Do not clean your product with chemicals including glass cleaner any type of air freshener...

Страница 6: ...ns regarding the safe use and handling of the equipment Damage Requiring Service Unplug this product from the wall power outlet and refer servicing to qualified service personnel under the following conditions If the power supply cord or plug is damaged If liquid has been spilled or objects have fallen into the product If the product has been exposed to rain or water If the product does not operat...

Страница 7: ... such as bookcase or rack Ventilation required DISCONNECTING DEVICE FROM MAINS Mains plug is the disconnecting device The plug must remain readily operable Do not place anything containing liquid on top of the product such as flowerpot cup cosmetics or candle This may cause a fire hazard PCS500R Rack Installation See p 15 16 Wear a properly grounded antistatic wrist strap to avoid causing electros...

Страница 8: ...m on each side including top and bottom of the PCS500R Do NOT stack other equipment on the top of the PCS500R Also ensure that the unit s AC power adapter is never stacked or bundled with other AC power adapters Each adapter should have adequate ventilation and should be isolated from other heat sources Circuit Overloading Consideration should be given to the connection of the equipment to the sup...

Страница 9: ...This capability provides output of up to 21 programmes of video content ISDB T RF output In addition to the GEM site data channel the PCS500R generates up to one Java application or two HTML application RF channels for video playout Each of these channels supports either two or three programme streams multiplexed on each channel This capability provides output of up to three Java application or si...

Страница 10: ...ted to one half or one third of the output channel bitrates Mbps which in turn are dependent on the modulation format 256 QAM modulation supports up to 38 8 Mbps per channel and 64 QAM modulation supports up to 26 97 Mbps per channel Create a channel assignment plan for the installation site or modify an existing plan to incorporate the RF output of the PCS500R Ensure that up to eight contiguous C...

Страница 11: ...y for the PCS500R is 861000 KHz Find a location on the frequency spectrum that is free of existing noise Video Channel Assignments for RF Output ISDB T Each input programme is limited to one half or one third of the output channel bitrates Mbps ISDB T modulation supports up to 23 23 Mbps 6 MHz bandwidth per channel Create a channel assignment plan for the installation site or modify an existing pl...

Страница 12: ...ed for the PCS500R IP output The IP start channel is user assigned in the Admin Client and the remaining channel assignments are then automatically incremented For example if the IP start channel assignment is 227 0 0 40 the remaining channels will be 227 0 0 41 227 0 0 42 etc Since the first two streams are reserved for site data the first video content channel in this scenario will be 227 0 0 42...

Страница 13: ...V DC RF TAP RF OUT AC power Cord Adapter 0 dBmV Disconnect Device The AC mains plug is used as the disconnect device The disconnect device must remain readily operable RF TAP Connector Reserved for service technician use only When not in use this connector must remain terminated with attached terminator accessory ...

Страница 14: ...of the PCS500R Do NOT stack other equipment on the top of the PCS500R Screws with Lock Washers Only qualified service personnel should handle and install the PCS500R A series of screws with lock washers are used to secure the top and bottom covers of the PCS500R Use caution when handling the unit as the lock washers may have rough edges Do NOT run your fingers over the top and bottom covers of the...

Страница 15: ...you wish to change the location orientation of the mounting brackets carefully remove each of the four M4 x 10 mm screws and attendant washers one flat and one lock washer per screw holding each bracket in place Then use the same screws and washers to reattach the mounting brackets in the desired location 3 Carefully slide the chassis into a standard 48 2 cm equipment rack 4 Use all four mounting ...

Страница 16: ...heating leave at least 2 5 cm on each side including top and bottom of the PCS500R Do NOT stack other equipment on the top of the PCS500R unit Also ensure that the unit s AC power adapter is never stacked or bundled with other AC power adapters Each adapter should have adequate ventilation and should be isolated from other heat sources C Circuit Overloading Consideration should be given to the con...

Страница 17: ...llation procedure In some instances configuration steps must be performed before physical connections are made Typical Setup Diagram for PCS500R with RF Output Service Port USB POWER 19 V DC RF OUT RF TAP Control Port Feature Port PCS500R Service Port connection RF Cable Combiner RF Distribution System Switch Router Internet Laptop PC for installation purposes Laptop PC for remote management Room ...

Страница 18: ... Service Port USB PCS500R Service Port connection CAT5E Cable Room Receiver Switch Multicast IGMPv2 Switch with Gigabit ports Multicast IGMPv2 Router Ex 192 168 2 24 Router Ex 192 168 1 24 Internet Internet Laptop PC for installation purposes Laptop PC for remote management eth0 eth1 1000BaseT default Full Duplex ...

Страница 19: ...19 ENGLISH VPN Network Connections Overview Pro Centric VPN Server Internet VPN Client Internet VPN Laptop PC Pro Centric VPN Server VPN Client PCS500R ...

Страница 20: ...reen 3 Once the PWR LED is lit continuously no longer blinking use the FTDI TTL 232R 5V AJ cable to connect a PC to the Service Port on the PCS500R rear panel 4 Using HyperTerminal or an equivalent terminal emulation programme on the PC configure the serial port as follows Bits per second baud 115200 Data bits 8 Parity None Stop bits 1 Flow Control None Note To avoid configuration errors make sure...

Страница 21: ... the output configuration See View System Information on page 26 for further information Note If the Control Port network is configured for DHCP but the Control Port IP address is not displayed in the System Information display see note above refer to Network Setup troubleshooting information on page 42 If configured the DHCP server should assign an IP address to the Control Port once the PCS500R ...

Страница 22: ...net than the Control Port IP address but should be on the same network as the TVs Also while either IPv4 or IPv6 is supported for the Control Port the Feature Port must be configured on an IPv4 network Note Do not specify a gateway IP address for the Feature Port e When you are finished with network configuration for the selected port select highlight at the bottom right of the Edit Connection scr...

Страница 23: ...r IP distribution network depending on the PCS500R output option to be used RF output Connect RF OUT on the PCS500R to the RF distribution centre combiner and balance the RF signal so that the Pro Centric signal level at the TV s is between 0 to 7 dBmV IP output Connect a CAT5E or better Ethernet cable between the Feature Port on the PCS500R rear panel and the institution s IP distribution network...

Страница 24: ...g the FTDI TTL USB cable P N TTL 232R 5V AJ Plug the USB end of the cable into an open USB port on your PC If necessary install the device driver Plug the other end of the cable into the Service Port jack on the PCS500R rear panel Using HyperTerminal or an equivalent terminal emulation programme on the PC configure the serial port as follows Note To avoid configuration errors make sure the keyboar...

Страница 25: ...or via a direct connection to the PCS500R Service Port Once communication is established you should see a login prompt If the login prompt is not automatically displayed press to refresh the screen 2 At the prompt type and press 3 At the prompt type the admin password and press 4 At the prompt either Press to display the PCS500R Main Menu see example below Type the desired command and press The fo...

Страница 26: ...is the version and build number of the HTML application and y y y yyyyy is the version and build number of the Java application Note If RF output is configured for DVB C modulation the display will identify the RF frequency in KHz in place of the RF channel If IP output is configured the display will identify the multicast IP address in place of the RF fields It is recommended that you record this...

Страница 27: ...een deployed complete a boot cycle the TVs STBs automap themselves to the Pro Centric server using the Feature Port IP address If the Feature Port IP address is assigned by a DHCP server and the DHCP server experiences an interruption the IP address assignment may change and this will cause a Pro Centric interruption 1 Log in to the PCS500R as described on the previous page 2 At the prompt type an...

Страница 28: ...28 ENGLISH 4 In the next screen select highlight the port profile to modify and then press Once you select a port the Edit Connection screen for that port will be displayed for example ...

Страница 29: ...le either IPv4 or IPv6 is supported for the Control Port the Feature Port must be configured on an IPv4 network Note Do not specify a gateway IP address for the Feature Port 5 To change the port configuration from Automatic to Manual or vice versa select highlight the IPv4 Configuration field and press Then select the appropriate option or from the drop down menu 6 The next step depends on your se...

Страница 30: ...ress 9 Recommended Change the unused port configuration from to For example for the Feature Port select highlight the IPv6 Configuration field and press Then select Ignore from the drop down list of options 10 When you are finished select highlight at the bottom right of the Edit Connection screen and press 11 Repeat steps 4 to 10 for the second port as required When you are finished with port con...

Страница 31: ...hoose to use 1 Log in to the server as described on page 25 2 At the prompt type and press The system will display the Network Manager menu for example 3 Select highlight and press Note To exit the Network Manager and return to the Main Menu prompt without modifying any settings select You may also modify the Control and or Feature Port configuration from the Network Manager See Modify Network Set...

Страница 32: ...TUI Menu to modify the server s host name See Modify the Server Host Name via TUI on pages 31 for further information The most recent update determines the server s host name regardless of which command you choose to use 1 Log in to the server as described on page 25 2 At the prompt type and press The system will prompt you to type the new host name 3 Type the new host name and then press Avoid us...

Страница 33: ...priate option for your country and then press 6 The system will display the following prompt for a region followed by a list of options At the prompt type the number that corresponds to the appropriate option for your region and then press After you specify the time zone region the system displays an overview of your location selections and prompts for confirmation for example 7 Either Type and pr...

Страница 34: ...ear month day hour and minute respectively Note that each of these fields requires numerical values and the hour should be entered in 24 hour format Press after each entry If applicable you can also press at each prompt to accept the default value in square brackets Once you enter the minute value the system will display the new time and then prompt for confirmation for example 4 Either Type y and...

Страница 35: ...sfully the system displays confirmation Change the Portal Application This option enables you to change the portal application Java or HTML if necessary Caution This option will create a temporary system interruption and should be used only when necessary After you complete the procedure below you must perform a number of additional steps in the appropriate Admin Client i e the Admin Client for th...

Страница 36: ...l operation Type and press to return to the Main Menu without resetting the system at the current time however note that you must eventually reset the system in order to apply the new portal application configuration See Reset the System on page 40 when you are ready to reset the system Note If you intend to modify additional configuration settings during the current session you may wait until all...

Страница 37: ...eserved for GEM site data and Slot 3 is unused and is not shown in the display On servers configured with the Pro Centric Java application it is possible to add a site video to Slot 2 and so for these systems Slot 2 will appear in the system monitor display On the other hand it is not possible to add a site video to Slot 2 on servers that are configured with the Pro Centric Direct HTML application...

Страница 38: ...ded and followed by a space as shown in the Ping Commands With Flags example below If you did not specify the number of messages to send the system will continue to send ping messages and display data until you press Type and press to display information on ping command options See ping command usage information example below 3 Unlimited messages only When you are finished monitoring ping data pre...

Страница 39: ...nitiate the download and confirm progress for example 4 When the update is successfully completed reset the system see Reset the System on page 40 for further information Update the VPN Setup This option is only applicable for the Java portal application It enables you to update the VPN client via a serial link to the PCS500R The appropriate update file must be provided by LG the system will not t...

Страница 40: ...ly 1 Log in to the PCS500R as described on page 25 2 At the prompt type shut and press The system will prompt for confirmation 3 Either Type and press to shut down the system immediately The shutdown typically takes about a minute When the PCS500R is in its shutdown state the front panel LED will blink steadily green Type and press to return to the Main Menu without shutting down the system Reset ...

Страница 41: ...rves the feature set if installed 1 Log in to the PCS500R as described on page 25 2 At the prompt type and press The system will display a warning and then prompt for confirmation 3 Either Type and press to continue Type and press to return to the Main Menu without reinstalling the Pro Centric carousels If you opt to continue progress messages will be displayed as the carousels are restored to the...

Страница 42: ...urn and stay red Note When power is first applied to the PCS500R the PWR LED initially flashes red and then turns green blinking during boot up Network Setup If the network is configured for DHCP but the PCS500R has not been assigned an IP address i e the Ctrl IP field in the PCS500R System Information display is blank 1 Check the Control Port connector on the rear panel of the PCS500R Make sure t...

Страница 43: ...unicate with the PCS500R If DHCP is not enabled connect a PC to the PCS500R Service Port display the System Information and ensure the IP address shown in the Ctrl IP field is the IP address being used to communicate with the PCS500R If necessary update the Control Port configuration as described in this document Ensure your PC s IP address is on the same subnet as the PCS500R s IP address If nece...

Страница 44: ...nectors 2 75 Ohm Type F Frequency VHF UHF 54 865 MHz RF Output Span Up to 8 Contiguous Channels within 120 MHz span RF Output Frequency Range 54 MHz to 865 MHz Active Output Level at RF Out jacks 1 dBm 47 75 dBmV Typical Test Output Level 47 75 dBm 1 dBmV Typical Frequency Accuracy 5 ppm DC Input 19 V DC 2 2 Amps Ethernet Connector Control Port 10 100 1000BaseT RJ 45 Ethernet Connector Feature Por...

Страница 45: ...dard EN 300 429 V1 2 1 DVB C Constellations 64 QAM 256 QAM Symbol Rate 64 QAM 256 QAM 5 056 MBaud 64 QAM 256 QAM 6 111 MBaud 64 QAM 256 QAM 6 9 MBaud Standard ABNT NBR 15601 2007 ISDB T Parameters 64 QAM 7 8 Convolutional Code 1 32 Guard Interval Ratio 2K FFT 13 Segments Sample Rate 8 126984Ms s AC DC Adapter Manufacturer APD Model DA 65G19 Input AC 100 240 V 50 60 Hz Output DC 19 V 3 42 A ...

Страница 46: ...yright abrt 2 1 11 GPL 2 0 Copyright c 2014 ABRT team abrt addon ccpp 2 1 11 GPL 2 0 abrt addon kerneloops 2 1 11 GPL 2 0 abrt addon pstoreoops 2 1 11 GPL 2 0 abrt addon python 2 1 11 GPL 2 0 abrt addon vmcore 2 1 11 GPL 2 0 abrt addon xorg 2 1 11 GPL 2 0 abrt cli 2 1 11 GPL 2 0 abrt console notification 2 1 11 GPL 2 0 abrt dbus 2 1 11 GPL 2 0 abrt libs 2 1 11 GPL 2 0 abrt python 2 1 11 GPL 2 0 ab...

Страница 47: ...0 Copyright c 1998 2001 2003 2014 Free Software Foundation Inc binutils 2 23 52 0 1 GPL 3 0 Copyright c 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 Free Software Foundation Inc biosdevname 0 6 2 GPL 2 0 Copyright c 2006 Dell Inc by Matt Domsch Matt_ Domsch dell com blktrace 1 0 5 GPL 2 0 Copyright c 2005 Jens Axboe axboe suse de Copyright c 2006 J...

Страница 48: ...Copyright c 2009 2014 Milan Broz dbus 1 6 12 GPL 2 0 dbus glib 0 1 GPL 2 0 desktop file utils 0 22 GPL 2 0 Copyright c 2007 2009 Vincent Untz vuntz gnome org device mapper 1 02 107 GPL 2 0 LGPL 2 1 device mapper persistent data 0 5 5 GPL 3 0 diffutils 3 3 GPL 3 0 Copyright c 1992 1993 1994 1995 1996 1998 2001 2002 Free Software Foundation Inc dmidecode 2 12 GPL 2 0 dmraid 1 0 0 rc16 GPL 2 0 dnsmas...

Страница 49: ...holas d nunley intel com amd8111e support by Reeja John reeja john amd com long arguments by Andi Kleen SMSC LAN911x support by Steve Glendinning steve glendinning smsc com Rx Network Flow Control configuration support santwona behera sun com Various features by Ben Hutchings bhutchings solarflare com Copyright c 2009 2010 Solarflare Communications MDI X set support by Jesse Brandeburg jesse brand...

Страница 50: ...achowicz Copyright c 2008 Alberto Ruiz Copyright c 1999 Mark Crichton Copyright c 1999 2001 Tim Janik gettext 0 18 2 1 GPL 3 0 LGPL 2 1 Copyright c 1998 2010 2013 Free Software Foundation Inc GLib 2 42 2 LGPL 2 1 glib networking 2 42 0 LGPL 2 1 Copyright c 2011 Collabora Ltd Copyright c 2011 2013 Red Hat Inc glibc 2 17 LGPL 2 1 gmp 6 0 0 LGPL 3 0 GNU nano an enhanced clone of the Pico text editor ...

Страница 51: ...kes debian org hunspell 1 3 2 LGPL 2 1 hunspell 0 20121024 LGPL 2 1 hwdata 0 252 GPL 2 0 initscripts 9 49 30 GPL 2 0 iproute2 3 10 0 GPL 2 0 Copyright c 2009 Alexey Kuznetsov iprutils 2 4 8 CPL 1 0 Copyright c 2000 2004 International Business Machines Corporation and others iptables 1 4 21 GPL 2 0 iputils 2 GPL 2 0 irqbalance 1 0 7 GPL 2 0 jbigkit libs 2 GPL 2 0 kbd 1 15 5 GPL 2 0 kexec tools 2 0 ...

Страница 52: ...ald Welte Pablo Neira Ayuso libmodman 2 0 1 LGPL 2 1 libmount 2 23 2 LGPL 2 1 libndp 1 2 LGPL 2 1 Copyright c 2013 2015 Jiri Pirko jiri resnulli us libnetfilter conntrack 1 0 4 GPL 2 0 Copyright c 1999 2014 Harald Welte Pablo Neira Ayuso libnfnetlink 1 0 1 GPL 2 0 Copyright c 2001 2005 Netfilter Core Team coreteam netfilter org libnl 3 2 21 LGPL 2 1 Copyright c 2003 2013 Thomas Graf tgraf suug ch ...

Страница 53: ...ndation Inc libteam 1 17 LGPL 2 1 Copyright c 2011 2015 Jiri Pirko jiri resnulli us libthai 0 1 14 LGPL 2 1 libtool 2 4 2 LGPL 2 1 libunistring 0 9 3 LGPL 3 0 libusb 0 1 4 LGPL 2 1 Copyright c 2008 Daniel Drake dsd gentoo org Copyright c 2000 2003 Johannes Erdfelt johannes erdfelt com libusbx 1 0 15 LGPL 2 1 libuser 0 60 LGPL 2 1 Copyright c 2000 2002 2007 2008 Red Hat Inc libutempter 1 1 6 LGPL 2...

Страница 54: ...GPL 2 0 mdadm 3 3 2 GPL 2 0 microcode_ctl 2 1 GPL 2 0 mjet ko 3 2 GPL 2 0 Copyright c 2012 2013 Zenith LG Electronics mlocate 0 26 GPL 2 0 mozjs 17 0 0 MPL 2 0 mtr 0 85 GPL 2 0 multipath tools 0 4 9 GPL 2 0 net tools 1 6 GPL 2 0 Copyright c 1997 1999 2000 Andi Kleen Copyright c 1994 John Paul Morrison VE7JPM nettle 2 7 1 LGPL 2 1 NetworkManager 1 0 6 GPL 2 0 newt 0 52 15 LGPL 2 1 newt python 0 52 ...

Страница 55: ...u do not wish to do so delete this exception statement from your version os prober 1 58 GPL 2 0 pango 1 36 8 LGPL 2 1 Copyright c 1999 Red Hat Software parted 3 1 GPL 3 0 pciutils 3 2 1 GPL 2 0 Copyright c 1997 2013 Martin Mares mj ucw cz php56u pear 1 10 1 LGPL 3 0 pinentry 0 8 1 GPL 2 0 Copyright c 2002 g10 Code GmbH Copyright c 2001 Free Software Foundation Inc Copyright c 1992 2002 Trolltech A...

Страница 56: ...pulseaudio 6 LGPL 2 1 pygobject2 2 28 6 LGPL 2 1 pygobject3 base 3 14 0 LGPL 2 1 pygpgme 0 3 LGPL 2 1 pyliblzma 0 5 3 LGPL 3 0 python augeas 0 5 0 LGPL 2 1 python chardet 2 2 1 LGPL 2 1 python dmidecode 3 10 13 GPL 2 0 python kitchen 1 1 1 LGPL 2 1 python perf 3 10 0 GPL 2 0 python pycurl 7 19 0 LGPL 2 1 python pyudev 0 15 LGPL 2 1 python slip 0 4 0 GPL 2 0 python systemd 219 LGPL 2 1 python urlgr...

Страница 57: ...selinux policy 3 13 1 GPL 2 0 selinux policy targeted 3 13 1 GPL 2 0 setserial 2 17 GPL 2 0 Copyright c 1994 by Theodore Ts o tytso mit edu setuptool 1 19 11 GPL 2 0 sgpio 1 2 0 10 GPL 2 0 shadow utils 4 1 5 1 GPL 2 0 shared mime info 1 1 GPL 2 0 slang 2 2 4 GPL 2 0 smartmontools 6 2 GPL 2 0 sos 3 2 GPL 2 0 sssd 1 13 0 GPL 3 0 SwingX 1 6 LGPL 2 1 Copyright c 2005 2006 Sun Microsystems Inc sysstat ...

Страница 58: ... yum metadata parser 1 1 4 GPL 2 0 yum utils 1 1 31 GPL 2 0 To obtain the source code under GPL LGPL MPL and other open source licenses that is contained in this product please visit https opensource lge com In addition to the source code all referred license terms warranty disclaimers and copyright notices are available for download LG Electronics will also provide open source code to you on CD R...

Страница 59: ...re Foundation Apache Tomcat 6 Apache 2 0 apr 1 5 4 Apache 2 0 Copyright c 2008 2016 The Apache Software Foundation apr 1 5 2 Apache 2 0 apr 1 4 8 Apache 2 0 Copyright c 2008 2016 The Apache Software Foundation apr util 1 5 2 Apache 2 0 BIND 9 9 4 ISC Copyright c 2017 Internet Systems Consortium Boost 1 53 0 BSL 1 0 Copyright c Beman Dawes David Abrahams 1998 2005 Copyright c Rene Rivera 2004 2007 ...

Страница 60: ...Inc freetype 2 4 11 FTL Copyright c 2006 2015 by David Turner Robert Wilhelm and Werner Lemberg giflib 4 1 6 MIT Copyright c 1997 Eric S Raymond gsm 1 0 13 MIT harfbuzz 0 9 36 MIT like License HarfBuzz httpd 2 4 6 Apache 2 0 Copyright c 1997 2015 The Apache Software Foundation httpd 2 4 20 Apache 2 0 Copyright c 1997 2015 The Apache Software Foundation httpd 2 4 18 Apache 2 0 Copyright c 1997 2015...

Страница 61: ...it 3 BSD 3 Clause Copyright c 1999 Precision Insight Inc Cedar Park Texas Copyright c 2000 VA Linux Systems Inc Sunnyvale California libffi 3 0 13 MIT Copyright c 1996 2012 Anthony Green Red Hat Inc and others libfontenc 1 1 2 MIT Copyright c 1998 2001 by Juliusz Chroboczek libjpeg turbo 1 2 90 IJG Copyright c 2009 2016 D R Commander libnghttp2 1 7 1 MIT libogg 1 3 0 BSD 3 Clause Copyright c 2002 ...

Страница 62: ... Project authors libX11 1 6 3 X11 Copyright c 1985 1986 1987 1988 1989 1990 1991 1994 1996 2002 The Open Group libxml2 2 9 1 MIT Copyright c 1998 2003 Daniel Veillard libxslt 1 1 28 MIT like License libxslt Copyright c 2001 2002 Thomas Broyer Charlie Bozeman and Daniel Veillard Linux PAM 1 1 8 BSD 3 Clause Copyright c YEAR Linux PAM Project Copyright c Andrew G Morgan 1997 morgan parc power net ls...

Страница 63: ... 2003 David Corcoran corcoran musclecard com Copyright c 2001 2011 Ludovic Rousseau ludovic rousseau free fr perl 5 16 3 Artistic 1 0 Perl Copyright c 1993 2017 by Larry Wall and others perl Carp 1 26 Artistic 1 0 Perl perl Compress Raw Bzip2 2 061 Artistic 1 0 Perl perl Compress Raw Zlib 2 061 Artistic 1 0 Perl perl constant 1 27 Artistic 1 0 Perl perl Data Dumper 2 145 Artistic 1 0 Perl perl DBD...

Страница 64: ...tors 2 5 1 Artistic 1 0 Perl perl Scalar List Utils 1 27 Artistic 1 0 Perl perl Socket 2 01 Artistic 1 0 Perl perl Storable 2 45 Artistic 1 0 Perl perl Text ParseWords 3 29 Artistic 1 0 Perl perl threads 1 87 Artistic 1 0 Perl perl threads shared 1 43 Artistic 1 0 Perl perl Time HiRes 1 9725 Artistic 1 0 Perl perl Time Local 1 23 Artistic 1 0 Perl php56u 5 6 21 PHP 3 01 php56u cli 5 6 21 PHP 3 01 ...

Страница 65: ... 01 BSD 4 Clause Copyright c 1980 1990 Regents of the University of California Copyright c 2000 2001 Silicon Graphics Inc SGI rfkill 0 4 ISC sg3_utils libs 1 37 BSD 3 Clause Copyright c 1999 2010 Douglas Gilbert snappy 1 1 0 BSD 3 Clause Copyright 2011 Google Inc strace 4 8 BSD 3 Clause Copyright c 1991 1992 Paul Kranenburg pk cs few eur nl Copyright c 1993 Branko Lankester branko hacktic nl Copyr...

Страница 66: ...91 1993 1998 The Open Group xorg lib libICE 1 0 9 MIT like License libICE Copyright c 1993 1998 The Open Group xorg lib libpciaccess 0 13 4 ISC MIT X11 Copyright c 2008 Juan Romero Pardines Copyright c 2008 2011 Mark Kettenis Copyright c 2009 Michael Lorenz Copyright c 2009 2012 Samuel Thibault Copyright c IBM Corporation 2006 2007 Copyright c Eric Anholt 2006 Copyright c Mark Kettenis 2011 Copyri...

Страница 67: ... Corporation Copyright c 2002 Hewlett Packard Inc Copyright c 2006 Intel Corporation Copyright c 2008 Red Hat Inc Copyright c 2011 Dave Airlie Copyright c 2006 Keith Packard xorg lib libXrender 0 9 8 HPND Copyright c 2001 2003 Keith Packard Copyright c 2000 SuSE Inc xorg lib libxshmfence 1 2 HPND Copyright c 2013 Keith Packard xorg lib libXt 1 1 4 HPND Copyright c 2001 2003 Keith Packard Copyright...

Страница 68: ...he control of LG Any alteration of the product after manufacture voids this warranty in its entirety THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND LG SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INDIRECT OR INCIDENTAL DAMAGES OF ANY KIND INCLUDING LOST REVENUES OR PROFITS IN CONN...

Страница 69: ... Pro Centric logo and the LG logo are registered trademarks of LG Electronics Inc Java and the Java Powered logo are trademarks of Oracle All other trademarks or registered trademarks are the property of their respective owners ...

Страница 70: ......

Отзывы: