16
ENGLISH
Front View of Rack Cabinet
PWR
2.5 cm minimum
2.5 cm minimum
Rack-mount Considerations
A. Elevated Operating Ambient
If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer (see
specifications information in this document).
B. Reduced Air Flow
Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of
the equipment is not compromised. To ventilate the system normally and avoid overheating, leave at least 2.5
cm on each side (including top and bottom) of the PCS500R. Do NOT stack other equipment on the top of the
PCS500R unit. Also, ensure that the unit’s AC power adapter is never stacked or bundled with other AC power
adapters. Each adapter should have adequate ventilation and should be isolated from other heat sources.
C. Circuit Overloading
Consideration should be given to the connection of the equipment to the supply circuit and the effect that
overloading of the circuits might have on overcurrent protection and supply wiring.
D. Reliable Earthing
Maintain reliable earthing of rack-mounted equipment. Particular attention should be given to supply
connections other than direct connections to the branch circuit (e.g., use of power strips).
E. Mains Outlet Earthing
The apparatus with Class I construction must be connected to a mains socket outlet with a protective earthing
connection.