24
|
PRODUCT DATA
Product Data
Due to our policy of continuous product innovation, some specifications may change without notification.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
Table 11: Indoor Units—Controls and Options
INDOOR UNIT TYPE
W
all Mounted—
Standard Finish
W
all Mounted—
AR
T COOL™ Mirror
1 Way Cassette
2 Way Cassette
4 Way Cassette
Ducted High Static
Ducted Low Static—
Slim Convertible
Ducted Low Static—
Bottom
Return
Vertical Air
Handler
(NJ)
Vertical Air
Handler
(NK)
Ceiling Suspended
Convertible
Surface Mount
Floor Mount—Cased
Floor
Mount—
Uncased
Nominal Chassis Size (Btu/h)
7–24
7–24
7–12
18–24
5–18
24–48
7–96
7–24
7–24
1.5–3
3.5–4.5
9–24
9–24
7–24
7–24
Air
fl
ow
Air supply outlets
1
1
1
2
4
4
1
1
1
1
1
1
1
1
1
Air
fl
ow direction (left/right)
manual/
auto
auto
manual manual
Auto air
fl
ow direction (up/down)
√
√
√
√
√
√
√
√
Fan speed (Heating mode)
3
3
4
4
4
4
3
3
3
3
3
3
3
3
3
Fan speed (Cooling mode)
4
4
5
5
5
5
3
3
3
3
3
4
4
3
3
Fan speed (fan mode)
3
3
4
4
4
4
3
3
3
3
3
3
3
3
3
Chaos swing (random louver swing)
√
√
Chaos wind (random fan speed)
√
√
√
√
√
√
√
√
Swirl wind (alternating louver)
√
√
Jet-cool (power cooling)
√
√
√
√
√
√
√
√
Operation
E.S.P. control
√
√
√
√
√
√
√
√
√
√
√
High ceiling
√
√
√
√
√
√
Auto-restart after power restore
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Hot Start
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Diagnostics
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Soft Dry (dehumidi
fi
cation)
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Auto changeover
1,5
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Auto operation
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Auto clean (coil dry)
√
√
√
√
Child lock
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Forced operation
√
√
√
√
√
√
√
√
√
√
Group control – Requires the use of one Group
Control Cable Kit (PZCWRCG3) for every ad-
ditional indoor unit
√
√
√
√
√
√
√
√
√
√
√
√
√
Sleep mode
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Timer (on/off)
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Weekly schedule
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Two thermistor control
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Test operation mode
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Filter
Washable pre-
fi
lter
√
√
√
√
√
√
√
√
√
√
√
√
√
Plasma
√
√
√
√
√
√
Controllers
7-day programmable controller
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
Simple controller with mode
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
Simple controller without mode
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
Wireless hand held controller
o
o
o
o
o
o
o
1
o
1
o
1
o
o
o
1
o
1
Others
Condensate lift
√
√
√
√
√
√
√
Ventilation air
√
√
2
√
2
√
√
√
√
√
Side branch ducting
√
3
√
3
Casing
√
√
√
√
√
√
√
√
√
Standard grille
√
√
√
√
Auto elevation grille
√
4
Colors
√
6
Suction grille
o
Suction canvas
o
Aux Heat Kit
√
√
GENERAL DATA
1.
Requires 7-day programmable zone controller.
2.
Optional ventilation kit PTVK430 or PTVK420 (Tempera-
ture, humidity, and volume limitations apply).
3.
Branch location and static pressure requirements app.
4.
Requires standard grille.
5.
Only with heat recovery system.
6.
Mirror panel comes standard (smoke gray). Silver and
blue panels are optional. Refer to Multi V Catalog.
√
= Standard feature
o = Unit option
Indoor Units—Controls and Options