5-20
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Abnormal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Normal
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)
Check high vol-
tage transformer
Output is full power
when you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Normal
Check high vol-
tage capacitor.
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Normal
Check high vol-
tage diode.
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
NOTE : • Make sure the wire leads correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Содержание MD-2642KT
Страница 33: ...6 2 13536A 13552A 13213A 13581A 14890A 14970A 14026A 15006A 268712 WTP004 23506A 13720D DOOR PARTS ...
Страница 34: ...6 3 WTP004 268712 23506A CONTROLLER PARTS ...
Страница 35: ...6 4 WTP013 35889A 34370T 36549S 33390G WTT010 WTT021 33052A 33112U OVEN CAVITY PARTS ...
Страница 36: ...6 5 WSZ085 56912B 55262A 44510A 43500A 466001 466003 466001 43501A LATCH BOARD PARTS ...
Страница 38: ...6 7 56170D 63303A WSZ002 WTT021 WTT028 647781 65006A 63302A WTT021 BASE PLATE PARTS ...
Страница 41: ...8 2 MAIN PRINTED CIRCUIT BOARD ...
Страница 42: ...8 3 KEY PRINTED CIRCUIT BOARD ...
Страница 43: ...P NO 3828W5S3131 April 2003 Printed in Korea ...