CIRCUIT DESCRIPTION
GENERAL DETAILS
• The low voltage transformer supplies the necessary
voltage to the micom controller when power cord is
plugged in.
• When the door is closed, the primary switch is ON, the
secondary switch is ON, and the monitor switch opens
(contact COM and NO).
WHEN SELECTING COOKING POWER
LEVEL AND TIME
• The micom controller memorizes the function you set.
• The time you set appears in the display window.
• Each indicator light turns on to indicate that the stage
has been set.
WHEN TOUCHING THE START PAD
• The coil of the relay is energized by the micom controller.
• Power input is supplied to the high voltage transformer
through the fuse to the primary switch and relay 2.
• Turntable rotates.
• The fan motor rotates and cools the magnetron by
blowing the air (coming from the intake on the base-
plate).
• The air is also directed into the oven to exhaust the
vapor in the oven through the upper plate.
• Cooking time starts counting down.
• 3.3 volts AC is generated from the filament winding of the
high voltage transformer. This 3.3 volts is applied to the
magnetron to heat the magnetron filament through two
noise-preventing choke coils.
• A high voltage of approximately 2100 volts AC is
generated in the secondary of the high voltage
transformer which is increased by the action of the high
voltage diode and charging of the high voltage capacitor.
• The negative 4,000 Volts DC is applied to the filament of
the magnetron.
WHEN THE OVEN IS SET AT ANY LEVEL
EXCEPT MAXIMUM.
• The micom controller controls the ON-OFF time of relay
2 by the applied signal to vary the average output power
of microwave oven as POWER LEVEL.
(refer
to page 1-1)
• One complete cycle of relay 2 is 22 seconds.
WHEN THE DOOR IS OPENED DURING
COOKING
• Both the primary switch and relay 2 cut off the primary
winding voltage of the high voltage transformer.
• ON-OFF of relay 2 is coupled electrically with opening
and closing of the secondary switch.
• When the door is opened, the secondary switch is
opened and when the door is closed, the secondary
switch is closed.
• The cooking time stops counting down.
• Relay stops functioning.
• As the door is opened, if the contact of primary switch
and relay2 and/or secondary switch fail to open, the fuse
opens due to the large current surge caused by the
monitor switch activation, which in turn stops magnetron
oscillation.
4-4
L
FUSE
H.V.
TRANS-
FORMER
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
PRIMARY
SWITCH
MONITOR
SWITCH
N
L
FUSE
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
PRIMARY
SWITCH
MONITOR
SWITCH
H.V.
TRANS-
FORMER
N
Содержание MD-2642KT
Страница 33: ...6 2 13536A 13552A 13213A 13581A 14890A 14970A 14026A 15006A 268712 WTP004 23506A 13720D DOOR PARTS ...
Страница 34: ...6 3 WTP004 268712 23506A CONTROLLER PARTS ...
Страница 35: ...6 4 WTP013 35889A 34370T 36549S 33390G WTT010 WTT021 33052A 33112U OVEN CAVITY PARTS ...
Страница 36: ...6 5 WSZ085 56912B 55262A 44510A 43500A 466001 466003 466001 43501A LATCH BOARD PARTS ...
Страница 38: ...6 7 56170D 63303A WSZ002 WTT021 WTT028 647781 65006A 63302A WTT021 BASE PLATE PARTS ...
Страница 41: ...8 2 MAIN PRINTED CIRCUIT BOARD ...
Страница 42: ...8 3 KEY PRINTED CIRCUIT BOARD ...
Страница 43: ...P NO 3828W5S3131 April 2003 Printed in Korea ...