5-10
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
1. Check DC 9V battery before performing
tests.
2. Select the DCV scale on the meter.
3. Using the meter, battery, and jump wire,
connect the items as illustrated in figures.
• Terminal to terminal.
1. Check DC 9V battery before performing
tests.
2. Select the DCV scale on the meter.
3. Using the meter, battery, and jump wire,
connect the items as illustrated in figures.
• Terminal to case.
Normal: Approximately 9V
Normal: Approximately 0V or
a value displayed in
mV Will be seen.
NOTE: When testing the magnetron, be sure to install the magnetron
gasket in the correct position and be sure that the gasket is in
good condition.
Antenna
Gasket
Chassis
Filament