5-15
NOTE: A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
(3) CHECKOUT PROCEDURES FOR CIRCUIT
BOARD
The following symptoms indicate a defective circuit
board.
(1) The start function fails to operate but the high
voltage Systems, the interlock switches, the
door sensing and the relay check good.
(2) The unit with a normal relay continuously
operates.
(3) The buzzer does not sound or continues to
sound.
(4) Some segments of one or more digits do not light
up, or they continue to light up, or segments light
when they should not.
(6) Wrong figures appear.
(7) The figures of all digits flicker.
(8) Some of the indicators do no light up.
(9) The clock does not keep time properly.
Содержание MD-2642KT