general inStallation guidelineS
Follow the procedure and best practices when mounting the indoor
unit’s plate to a wall.
Procedure
1. Mount the installation plate horizontally by aligning the centerline
using a leveling tool (Figure 19).
2. Use type “A” screws when mounting the plating (these screws
come with the plate).
• If mounting the unit on concrete wall, use field supplied anchor bolts.
3. Observe the left and right rear piping clearance when drilling into
the wall, as shown in Figure 20.
Mounting of Indoor Unit Installation Plate
Mounting installation Plate to Wall (Mega 115V - HxV Models)
Installation Plate
Chassis
Hook
Type "A" Screws
Figure 19: Installation Plate - Mounting Mega 115V
Figure 20: Installation Plate - Mega 115V
Ø2-19/32
Right Rear
Piping
Left Rear
Piping
Installation Plate
Place a level on raised tab
Unit: Inch
9-
21/32
5-11/32
16-
8/32
18-
29/32
Unit Outline
Ø2-19/32
4-
27/32
7
090HXV, 120HXV
Refer to
“Drilling Piping Hole in the Wall” on page 28
as
you follow procedure to install plate.
Select location carefully. Unit should be anchored to a strong wall to pre-
vent unnecessary vibration.
•
When choosing a location for the wall mount plate, be sure to take
into consideration routing of wiring for power outlets within the wall.
Contacting wiring can cause serious bodily injury, or death.
•
Use caution when drilling holes through the walls for the purposes
of piping connections. Power wiring can cause serious bodily injury,
or death.