Cooling Model
• Operation
• Timer Mode
• Soft Dry Mode
• Outdoor Unit Operating or not
- 14 -
Display Function
Operation Indicator
Timer Indicator
Soft Dry Indicator
Outdoor Unit Operation
OUT
DOOR
Self-diagnosis Function
1
(once)
(twice)
(5times)
3sec
3sec
3sec
3sec
3sec
3sec
2
3
Error
Code
Error LED
(Indoor body operation LED)
Error contents
SVC check point
• Indoor suction temperature
thermistor open/short.
• Indoor pipe temperature
thermistor open/short.
• Indoor TH ass'y check
• Outdoor TH ass'y
check
• Communication
line/circuit check
• Outdoor suction temperature
thermistor open/short.
• Outdoor pipe temperature
thermistor open/short.
• Poor communication
■
Error Indicator
• The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.
• Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
• If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.
• After error occurrence, if error is released, error LED is also released simultaneously.
• To operate again on the occurrence of error code 12, be sure to pull out power cord and then re-insert.
Содержание LM-2421C2L/A2L
Страница 1: ...Multi Type Room Air Conditioner SERVICE MANUAL MODEL LM 2421C2L A2L LM 3022C3L A3L ...
Страница 47: ... 47 Schematic Diagram 1 Indoor LM 2421C2L A2L LM 3022C3L A3L ...
Страница 48: ... 48 2 Outdoor 2 1 LM 2421C2L A2L ...
Страница 49: ... 49 2 2 LM 3022C3L A3L ...
Страница 56: ...P No 3828A20023G January 2002 Printed in Korea ...