- 18 -
2) Connection of Pipings
1. Remove the installation plate
• Pull the two '
∆
' marked portion of bottom of the
chassis and pull the installation plate out of chas-
sis.
2. Route the drain hose and the indoor tubing.
For right rear piping
3. Insert the pipings, the connecting cables and
the drain pipe through the piping hole on the
wall.
4. Connect the pipings and the indoor tubing, and
drain hose and drain pipe.
• Don't connect the cable to the indoor unit.
• Wrap the insulation material around the connect-
ing portion.
• Glue up the connection portion of drain hose and
drain pipe.
Installation plate
Pull
Pull
Pipe Size
Torque
Liquid Side (1/4")
1.8kg.m
Gas Side (1/2")
5.5kg.m
Pull
Press
Indoor unit tubing
Flare nut
Pipings
Spanner
Torque wrench
Plastic bands
Insulation material
Drain hose
Drain pipe
Adhesive
• To remove the holder, press
the bottom of the chassis
near the holder upwards
and the tab is clear of its
hole.
• Turn it clockwise approx.
90° and remove it.
Tubing holder