- 26 -
Connecting cable
2) Connect the cable to the indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
• Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively.
• LM-2421C2L/A2L
2. Attach the Grille onto the cabinet.
• Grasp lower the left and right side of the
Grille and engage four tabs on the top inside
edge of the chassis.
• Press the Grille toward the chassis until it will
be back into place.
Terminal on the OUTDOOR UNIT
Terminal on the INDOOR UNIT
Terminal on the INDOOR UNIT
Terminal on the INDOOR UNIT
A-UNIT
B-UNIT
C-UNIT
Power Cord
1(L)
1(L)
2(N)
2(N)
1(L)
2(N)
3
3
2(N)
3
3
1(L)
2(N)
3
1(L)
2(N)
3
2(N)
1(L)
1(L)
2(N)
1(L)
2(N)
3
3
1(L)
2(N)
3
1(L)
Terminal on the OUTDOOR UNIT
Terminal on the INDOOR UNIT
Terminal on the INDOOR UNIT
B-UNIT
A-UNIT
Power Cord
2(N)
2(N)
3
1(L)
• LM-3022C3L/A3L
Содержание LM-2421C2L/A2L
Страница 1: ...Multi Type Room Air Conditioner SERVICE MANUAL MODEL LM 2421C2L A2L LM 3022C3L A3L ...
Страница 47: ... 47 Schematic Diagram 1 Indoor LM 2421C2L A2L LM 3022C3L A3L ...
Страница 48: ... 48 2 Outdoor 2 1 LM 2421C2L A2L ...
Страница 49: ... 49 2 2 LM 3022C3L A3L ...
Страница 56: ...P No 3828A20023G January 2002 Printed in Korea ...