8-19
TROUBLESHOOTING
Replace the Main PCB
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode,
follow these steps:
(1) press the CLEAR button
(2) press the upper BAKE and BROIL buttons
at the same time
(3) press the upper BAKE and BROIL button
at the same time again.
(4) press the NUM 3 button
Normal: Thermistor value at room temp is
from 70˚F to 90˚F
Yes
No
Go to No 1
3
Plug in the unit
4
Current Oven Temp
Содержание LDG4313ST
Страница 50: ...6 1 COMPOSITION OF CONTROL 1 Wiring Diagram Main system PCB ...
Страница 53: ...6 4 COMPOSITION OF CONTROL NFC PCB NFC PCB P N EBR78789101 Buzzer PCB Buzzer PCB EBR76332902 ...
Страница 89: ...2034 2050 203L 203R 2051 2006 2501 260M 2001 260B 2381 260K 2043 2042 2044 2385 CONTROLLER PARTS EV ...