8-12
TROUBLESHOOTING
3
Yes
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode,
follow these steps:
(1) press the CLEAR button
(2) press the upper BAKE and
BROIL buttons at the same time.
(3) press the upper BAKE and
BROIL buttons at the same time again.
(4) press the NUM 3 button
Normal :
Themistor value at room temp is from
70˚F to 90
˚
F as the above figure.
Yes
Go to No 6
4
No
Range Of the resistance
Plug in the unit
Is the resistance of
thermistor normal?
Check:
Pins 4 and 5 of CN60 and pins 5 and 6 of CN61
in main PCB
Normal
- approximately 1.09k
Ω
at 77˚F(25˚C)
No
Replace the
defected
Themistor
5
Yes
Unplugged the unit
CN61
CN60
6
Replace the Main PCB
igniter
Resistance[
Ω
]
Approximately
Upper Broil
50~500
Upper Bake
50~500
Conv. Heater
45~400
Current Oven Temp