4. TROUBLE SHOOTING
- 58 -
Checking Flow
START
Is the connection of
FPCB with connector on
PCB(CN600) ok ?
YES
NO
Reassemble FPCB with CN600 connector
Check the connection LCD
module with connector
On FPCB ?
NO
Reassemble LCD module with connector on FPCB
Check the soldering of
CN600 ?
NO
Change the FPCB and try again
YES
YES
YES
Check the soldering of
EMI filter ?
Resoldering CN600
NO
Resoldering EMI filter(FL600~FL604)
Does LCD work
properly ?
NO
Replace LCD module
YES
LCD working well !
YES